Recessed LED Emergency Light with Dual MR-16 Heads – NYC Approved
Couldn't load pickup availability
RMW Series – Recessed Architectural LED Emergency Light with Dual MR-16 Heads
The RMW Recessed Architectural LED Emergency Light installs flush in suspended or drywall ceilings to maintain clean sightlines while meeting New York City emergency-code requirements. A rugged 20-gauge steel enclosure houses two fully adjustable 5 W MR-16 LED heads capable of 47.5 ft spacing. A sealed lead-calcium battery provides 90 minutes of emergency operation, and universal 120/277 VAC electronics ensure code-ready performance.
Download RMW LED Emergency Light Spec Sheet (PDF)
Features & Benefits
- New York City approved; CSA Listed to UL 924 for emergency lighting
- Flush recessed design with low-profile trim plate for modern interiors
- Dual 5 W MR-16 heads deliver 47.5 ft spacing at 10 ft mounting height
-
G2
Guardian diagnostics option for automated monthly testing
Illumination
- Two fully adjustable 5 W MR-16 LED bullet-style heads (PAR36 incandescent optional)
- 47.5 ft center-to-center spacing on a 3 ft path at 10 ft mounting height
Electrical
- Universal 120 / 277 VAC input, 50 / 60 Hz; solid-state two-rate charger
- Maintenance-free sealed lead-calcium battery – 90-minute runtime, 24-hour recharge
- Optional Ni-Cd battery available
- Low-voltage disconnect, brownout sensing, short-circuit and overcharge protection
Mounting
- Flush ceiling installation with torsion-spring secured trim plate
- Adjustable bar hangers for grid or drywall ceilings
Housing / Finish
- Heavy-duty 20-gauge steel back-box with powder-coated finish
- Trim finishes: White (
WH
) or Black (BL
)
Dimensions
- Trim plate: 10.2" L × 8.1" W
- Overall height to lamp tops: 9.5"
Warranty / Listings
- 5-year warranty on electronics and housing; battery prorated 5 years
- CSA Listed to UL 924; NFPA 101, NEC, and NYC compliant
Frequently Asked Questions
Is this fixture approved for NYC code compliance?
Yes. The RMW Series is certified to UL 924 and approved for use under NYC electrical and fire code.
How far apart can the lamp heads be spaced?
Each 5 W MR-16 head provides spacing up to 47.5 ft at 10 ft mounting height on a 3 ft path.
Can I use this for drywall and grid ceilings?
Yes. The unit includes adjustable hanger bars and torsion springs for recessed installs in both ceiling types.
Is a self-diagnostics option available?
Yes. Add the G2
Guardian diagnostics option for automated monthly, semiannual, and annual testing.
Product Features
- Architectural
- Brand: Exitronix
- Cold Weather
- LED
- Low Profile
- New York City Approved
- Product: RMW
- Recessed Lights
- Self Testing
- Vandal Proof