Exit Signs – Emergency & Fire

Exit signs are essential life-safety fixtures that mark egress routes during fires, power outages, and evacuations. Our selection includes UL 924-listed emergency exit signs and fire exit signs for corridors, stairwells, and exterior approaches. Our assortment includes: wet-location exit signs, edge lit exit signs, photoluminescent exit signs, and tritium self-luminous exit signs. Choose battery backup exit signs or AC-only, with wall mount exit signs, ceiling mount exit signs, and end mount exit signs in white housing exit signs or black housing exit signs.

UL 924 Exit Sign Red Letters / Green Letters Single / Double-Face Field-Selectable Arrows Wet-Location Rated NYC / Chicago Formats
Buyers Guide Tips

What to Look for in Exit Signs

  • Signage-only purpose: Exit signs mark the route and keep the EXIT legend visible during outages; they do not provide area illumination—use separate emergency lights where required. Install per UL 924/NFPA 101 and your AHJ.
  • Legend visibility & configuration: Standard 6-inch letters with ~100 ft typical viewing; choose red letters or green letters for contrast, specify single or double-face for sightlines, and set field-selectable arrows at install.
  • Power & upkeep (signs): Select AC-only (with central emergency power), 90-minute battery backup, or non-electrical self-powered designs. Optional self-testing on battery models automates monthly/annual checks; verify recharge time and indicator access for inspections.

Building owners, contractors, and safety professionals rely on compliant, reliable emergency exit signs to meet code and keep occupants safe. From slim architectural edge-lit styles to rugged metal cabinets and non-electrical options, we offer exit signage to match your building requirements.

💡 What is an emergency exit sign? A code-required fixture that clearly marks egress paths and remains visible during power failures—using batteries, central emergency power, or self-powered technology. For zero-maintenance choices, see our non-electrical exit signs.
Exit Signs Collection
Trust & Policies

Filters

55 Products

Exit Signs - Spec Guide

  • Exit sign standards: Specify UL 924–listed exit signs and install to NFPA 101. battery backup exit signs must keep the legend illuminated for 90 minutes; exit signs do not provide area lighting.
  • Exit sign legend & viewing: Use 6-inch exit sign letters with ~100 ft typical viewing. Choose red letters or green letters for contrast; set field-selectable exit sign arrows at install; pick single-face or double-face exit signs for corridor sightlines.
  • Exit sign power options: AC-only exit signs, battery backup exit signs, or non-electrical exit signs to reduce maintenance.
  • Environment & sealing for exit signage: For moisture/exterior approaches, use wet-location exit sign models; verify ambient temperature and enclosure (IP/NEMA) needs for the installation.
  • Exit sign housing & aesthetics: For architectural interiors, consider edge-lit exit sign styles or broader architectural exit signs. For durability, specify die-cast aluminum exit signs, steel exit signs, or thermoplastic exit signs. Common finishes include white housing exit signs and black housing exit signs.

FAQs About Exit Signs

How long must emergency exit signs stay on during a power outage?

Exit signs must stay illuminated for at least 90 minutes during a power failure, per UL 924 and NFPA 101 (OSHA references these life-safety standards as well).

What’s the difference between red letters and green letters?

Both are widely accepted—check your local code. Red letters are traditional; green letters can improve contrast in some interiors. Some jurisdictions (like NYC) require 8-inch red letters for specific applications.

Are exit signs required to have battery backup?

Most battery backup exit signs include a pack that keeps the legend lit for 90 minutes. Buildings with central emergency power (generator/inverter) can use AC-only models—confirm with your local inspector.

Do exit signs need arrows or directional indicators?

Yes—when the route isn’t obvious. Most signs include field-selectable chevrons you can set during installation to point left, right, or both.

Which mounting and housing colors are available?

Standard options include wall mount exit signs, ceiling mount exit signs, and end mount exit signs. Most models come in white housing exit signs and black housing exit signs to match interior finishes.