Hazardous-Location Emergency Light (Class I Div 2, NEMA 4X)
Couldn't load pickup availability
Got questions?
Give us a call 800-847-1955!
Hazardous-Location Emergency Light - Class I Div 2, NEMA 4X Fiberglass, Dual PAR36 Heads, 90 min Battery - Features & Specs
The CP-EMX Champion Extreme Hazardous-Location Emergency Light is built for environments where flammable gases or vapors may be present. This CSA-listed unit meets UL 924 and features a corrosion-resistant NEMA 4X fiberglass cabinet with two fully adjustable PAR36 lamp heads. Rated for Class I Div 2, Groups A–D, the CP-EMX delivers 90 minutes of reliable egress lighting for refineries, wastewater plants, and other industrial facilities.
Need a complete solution? Pair this with our hazardous location exit signs or browse all explosion proof emergency lights.
Key Features
- Hazardous-location rated: Class I Division 2, Groups A–D (T2B); suitable for Class I, Zone 2 IIA/IIB/IIC (T1/T2); CSA Listed; meets UL 924; NEMA 4X enclosure.
- Two fully adjustable PAR36 heads with 9 W tungsten lamps; impact-resistant, weatherproof housings.
- Corrosion-resistant fiberglass cabinet with stainless-steel breather valve; gray finish.
- Battery options: sealed lead-calcium or Ni-Cd; 90-minute emergency runtime; up to 48 hour max recharge (24 hour typical).
- 120/277 VAC input; low-voltage disconnect, brownout protection, magnetic test point.
- Mounting: four stainless feet for secure wall mounting; front-hinged access panel for service.
- Supports remote lamp loads via terminal connectors.
- Options: G2 self-test/diagnostics, side-mounted heads (SMH), 120/277 V time delay (TA/TB), tamper-resistant hardware (TRH), ammeter/voltmeter, fire-alarm interface.
- Compliance: meets UL 924 & CSA C860; NFPA 101 and NEC.
- BAA/ARRA compliant.
Related Wet-Location Guides
Spec Sheet
Download Hazardous Location Emergency Unit Spec Sheet (PDF)
Illumination
- Two fully adjustable PAR36 heads with 9 W tungsten lamps.
- Impact-resistant, weatherproof heads match the gray enclosure.
- Supports remote lamp loads via terminal connectors.
Electrical
- Dual-voltage 120/277 VAC input (60 Hz).
- Maintenance-free sealed lead-calcium or Ni-Cd battery; 90-minute emergency runtime.
- Recharge: up to 48 hours maximum (24 hours typical).
- Low-voltage disconnect, magnetic test point, and brownout protection.
Mounting
- Four stainless-steel mounting feet pre-installed for secure surface wall mounting.
- Front-hinged access panel simplifies installation and maintenance.
Housing / Construction
- One-piece fiberglass cabinet resists corrosion and chemical exposure.
- NEMA 4X housing with stainless-steel breather valve.
Options & Accessories
- G2 — Guardian self-test / diagnostics.
- SMH — Side-mounted heads.
- TA / TB — 120 V / 277 V time delay (5, 10, 20 min).
- TRH — Tamper-resistant hardware.
- A — Ammeter • V — Voltmeter • A11 — Fire alarm interface.
Dimensions
- 13.5" H × 15.5" W × 6.3" D (plus approx. 5.5" head stand-off)
Warranty / Listings
- Five-year warranty on electronics and housing; battery five-year prorated.
- CSA listed; meets UL 924, CSA C860, NFPA 101, and NEC.