400EX Die-Cast Aluminum LED Exit Sign with Battery Backup Option

SKU: 402EX-LB-BA
Regular price $226.30
Accepted payment methods include Visa, Mastercard, American Express, Discover, PayPal, Venmo, Apple Pay, Google Pay, Amazon Pay, and Shop Pay.

Got questions?

Give us a call 1-888-959-1965!

400EX Die-Cast Aluminum LED Exit Sign with Battery Backup - Red/Green, UL 924

The 400EX die-cast aluminum LED exit sign is an architectural commercial EXIT fixture for projects that need a durable metal housing, red or green 6 in LED letters, and a battery-backup option without moving to a specialty city-code sign. Use it for offices, schools, healthcare support areas, retail corridors, hospitality spaces, and tenant improvements where a low-profile aluminum sign is preferred over plastic signage.

The 402EX, 403EX, G402EX, and G403EX variant families cover single-face or double-face layouts, AC-only, 120 V, 277 V, or Ni-Cd battery backup power selections, brushed aluminum, black, or white finishes, 220-240 V export input, G2 self-testing, and TRH tamper-resistant hardware. For adjacent buying paths, compare die-cast aluminum exit signs, review battery backup exit signs, or check the UL 924 compliance guide.

Specs, documents, buying checks, related paths, and FAQs are organized below from product fields for easier review.

Buying support

Product details and buying checks

Before ordering 400EX, confirm face count, letter color, finish, power source, diagnostics, hardware, and local code approval.

  • UL 924
  • Die-Cast Aluminum
  • Red / Green Legend
  • Single / Double Face
  • Optional Ni-Cd / 90 min
  • 120/277V
  • Universal Mount
  • Damp Location
  • G2 Self-Testing
  • TRH Tamper-Resistant
  • Brushed / Black / White
  • CEC Title 20

Key features

  • 400EX architectural die-cast aluminum LED exit sign for commercial interiors that need a durable metal housing.
  • 402EX, 403EX, G402EX, and G403EX option families cover red and green letter configurations across single-face and double-face layouts.
  • 6 in stencil EXIT legend with 3/4 in stroke and long-life LEDs rated for 100,000 hours.
  • Universal mounting canopy supports ceiling, end, or wall installation from the same product family.
  • Concealed field-selectable chevron knockouts support final egress-arrow direction after route review.
  • AC-only, 120 V, 277 V, and WB Ni-Cd battery power selections support common commercial electrical schedules.
  • WB models provide 90-minute emergency runtime with about 24-hour recharge.
  • 2CI1 and 2CI7 dual-circuit options support 120 V or 277 V emergency-feed designs.
  • 220-240 V 50 Hz option supports export or special-voltage project requirements.
  • G2 Guardian self-test / self-diagnostics option monitors AC, battery, and LED status where selected.
  • TRH tamper-resistant hardware option supports schools, public corridors, and higher-abuse interior routes.
  • Brushed aluminum, black, and white finish packages coordinate with common architectural interiors.
Series 400EX
option families 402EX, 403EX, G402EX, and G403EX
Product type Die-cast aluminum LED exit sign with battery-backup option
Listing UL 924; damp-location rated
Legend Red or green 6 in LED EXIT letters with 3/4 in stroke
Face configuration Single-face or double-face configurations

Documents

Where the 400EX Fits Best

Choose the 400EX when a project needs a rugged architectural die-cast aluminum LED exit sign with a wide option matrix for power, diagnostics, finish, hardware, letter color, and face count. It is best for commercial interiors where metal construction and a low-profile finished look matter more than the lowest-cost thermoplastic option.

Legend, Face, and Visibility
  • Select red or green LED letters to match building plans, owner standards, and existing building signage.
  • Use single-face configuration above doors or wall-backed routes where the sign is viewed from one approach.
  • Use double-face configuration at corridor intersections, open areas, or projecting installations with two-way visibility.
  • Set chevrons after the final path-of-travel review so arrows match the approved egress route.
Power and Battery Backup
  • Use AC-only variants where a compliant building emergency source handles runtime outside the sign.
  • Use 120 V or 277 V selections for dual-circuit project schedules.
  • Use WB Ni-Cd battery variants when the sign itself must provide 90-minute emergency illumination.
  • Allow about 24 hours for recharge before full-duration battery testing.
  • Use 220-240 V 50 Hz variants where the electrical schedule requires special voltage.
Mounting and Chevron Setup
  • Universal canopy supports ceiling, end, or wall installation.
  • Confirm the junction box, sightline, and mounting orientation before ordering.
  • Concealed chevron knockouts let installers configure directional arrows in the field.
  • Consider wire guards or protective accessories where carts, public traffic, or abuse risk may affect the sign.
Housing, Finish, and Face Panels
  • Brushed aluminum finish supports more architectural door and corridor conditions.
  • Black finish options coordinate with darker interiors or contrast-driven design standards.
  • White finish options blend with typical walls, ceilings, and frames.
  • Die-cast construction and rounded soft-contour design help the sign feel more substantial than commodity plastic signage.
Diagnostics, Tamper Hardware, and Accessories
  • G2 Guardian self-testing monitors AC, battery, and LED status on eligible configurations.
  • TRH tamper-resistant hardware supports schools, public corridors, and other higher-abuse interior routes.
  • 2CI1 and 2CI7 options support dual-circuit input where emergency power is supplied separately.
  • Review the 400EX PDF before ordering so accessories, wiring, listings, and dimensions are captured together.
Listings, Warranty, and Maintenance
  • UL 924 listing and damp-location rating support standard indoor commercial egress applications.
  • Designed to support NFPA 101, NEC, OSHA, and CEC Title 20 project requirements where applicable.
  • 10-year warranty covers housing and electronics; battery coverage is 5-year prorated.
  • Document push-to-test, self-test, and full-duration emergency checks according to the maintenance plan.
Dimensions and Fit Checks
  • Housing measures 12.5 in wide x 8.5 in high x 2.1 in deep.
  • Verify clearance around door frames, ceiling features, wall returns, and conduit entries before ordering.
  • Confirm final face count, letter color, finish, power source, diagnostics, tamper hardware, and accessories in the project paperwork.
Compare Similar Die-Cast Exit Signs
  • Choose 400EX when a project needs the broad 402EX/403EX/G402EX/G403EX configuration matrix with battery, diagnostics, and tamper hardware options.
  • Choose 400U when the main priority is universal-mount die-cast flexibility with a simpler product path.
  • Choose thin or ultra-slim die-cast signs when lower projection and a slimmer profile are more important than the 400EX option set.
  • Choose NYC 8 in die-cast exit signs when the project requires larger red letters for New York City compliance.
  • Choose wet-location exit signs for exposed exterior, rain, hose-down, or severe moisture conditions.
Compliance notes
  • Confirm final fixture placement, face count, letter color, finish, power source, diagnostics, tamper hardware, accessories, and local code approval for the project.

Frequently asked questions

Is the 400EX exit sign UL listed and Title 20 compliant?

Yes. The 400EX family is UL 924 listed for damp locations and is designed to support CEC Title 20, NFPA 101, NEC, and OSHA requirements where applicable.

Can this die-cast aluminum exit sign be ceiling, end, or wall mounted?

Yes. The universal canopy supports ceiling, end, or wall installation. Confirm the actual junction box location and sightline before ordering.

Does every 400EX variant include battery backup?

No. AC-only, 120 V, 277 V, and WB Ni-Cd battery configurations are available. Choose a WB variant when the sign itself needs 90-minute emergency operation.

Which battery backup option is used on this model?

WB variants use a maintenance-free Ni-Cd battery for 90 minutes of emergency runtime with about 24-hour recharge.

Does the 400EX support self-testing diagnostics?

Yes. Select the G2 Guardian self-test / self-diagnostics option when the site needs automated monitoring of AC, battery, and LED status.

What finishes are available?

Common finish packages include brushed aluminum, black, and white, with matching or aluminum face-panel combinations depending on the selected variant.

Can I order tamper-resistant hardware?

Yes. Select the TRH option when the installation needs tamper-resistant exit sign hardware for schools, public corridors, or higher-abuse interior locations.

What do 2CI1 and 2CI7 mean?

2CI1 is the 120 V dual-circuit option and 2CI7 is the 277 V dual-circuit option. Use these where emergency power is supplied separately by the building system.