Edge-Lit Running Man Exit Sign - Surface/Recessed, CSA Listed
Couldn't load pickup availability
Got questions?
Give us a call 800-847-1955!
S900RM Edge-Lit Running Man Exit Sign - Surface/Recessed Overview
The S900RM edge-lit Running Man exit sign is a CSA listed pictogram sign for projects that need a clean acrylic panel, slim architectural housing, and a descriptive surface or recessed mounting path. Use it for commercial interiors, Canadian-style running-man egress layouts, tenant improvements, hospitality corridors, offices, schools, and healthcare support areas where a stencil-style EXIT sign is not the right visual standard.
This page now uses a descriptive product URL, structured specs, distinct buying checks, dedicated documents, related paths, and direct FAQs so long-tail searches can find the right details without repeating the same mounting, electrical, or compliance section content. The layout also keeps specifiers, installers, and buyers in separate decision lanes.
Buying support
Product details and buying checks
Review specs, pictogram setup, mounting choice, documents, related paths, and FAQs before ordering.
- CSA Listed
- UL 924
- Running Man
- Edge-Lit Acrylic
- Surface / Recessed
- 120/347 V
- NiMH Backup
- 90 min Runtime
- Damp Location
- Universal Pictograms
- Extruded Aluminum
- White / BA / Black
Key features
- Symbol-based wayfinding supports jobs that call for the running-man graphic rather than word-only EXIT signage.
- Light-guided acrylic presentation gives finished spaces a cleaner look than boxy stencil fixtures.
- Compact metal trim suits corridors, lobbies, tenant suites, hospitality areas, schools, and healthcare support spaces.
- One style family covers flush rough-ins and canopy-mounted conditions without changing the visual language.
- Installer-selectable inserts let the final route drawing drive the displayed direction.
- Local emergency operation and front test access support routine inspection workflows.
- Canadian commercial voltage support helps the product fit 347 V project schedules.
- Listing and protected-interior rating context support commercial submittal review.
- Finish choices coordinate with door hardware, ceiling grids, wall color, and exposed interiors.
- Manufacturer documents carry the exact rough-in, wiring, measurement, and warranty details for approval.
Documents
Application Fit
Specify S900RM when the job calls for a running-man pictogram sign with a clean edge-lit appearance instead of a text-only EXIT stencil. It fits finished commercial interiors, Canadian-style egress schedules, offices, hotels, schools, healthcare support spaces, and tenant corridors.
Surface vs Recessed Decision
- Use the Universal configurations where the sign will mount from a side-wall, ceiling, or canopy condition.
- Use the Recessed / White configuration where the project needs the sign to sit into the finished plane.
- Confirm rough-in space, viewing direction, and ceiling or wall conditions before selecting the mounting option.
Pictogram Direction Setup
- Select the stencil insert during installation to match the approved egress route.
- Use left-arrow or right-arrow panels only when directional routing is required.
- Use no-arrow panels where the exit path continues straight ahead or the sign is marking the exit point itself.
Finish Coordination
- White supports clean ceiling or wall applications and is the available finish for the recessed variant.
- Brushed aluminum supports a more architectural metal trim package on universal surface installations.
- Black can coordinate with darker ceilings, door frames, or exposed-finish interiors.
Power and Runtime Review
- Confirm that 120/347 V input matches the electrical schedule before release.
- Use the built-in NiMH backup where local 90-minute emergency operation is required at the sign.
- Allow the battery to complete its recharge cycle before full-duration emergency testing.
Submittal Checks
- Review the PDF and installation guide for exact wiring, rough-in, dimensions, pictogram setup, and warranty language.
- Confirm CSA, UL 924, damp-location, runtime, and AHJ acceptance requirements before approval.
- Choose a wet-location or high-abuse family for exterior, washdown, or impact-prone installations.
Compliance notes
- Confirm the selected variant and local approval path before release.
- Set symbol inserts only after final route drawings are approved.
- For rain, hose-down, vandal-prone, or other harsher conditions, choose a differently rated family.
Frequently asked questions
What is an edge-lit Running Man exit sign?
It is an exit sign that illuminates a running-man pictogram through an acrylic edge-lit panel instead of using text-only EXIT letters.
Is the S900RM surface mounted or recessed?
Both mounting paths are represented by the live variants. Universal models cover surface canopy conditions, while the Recessed / White model is built for recessed installation.
What voltage does the S900RM use?
S900RM uses 120/347 V, 50/60 Hz input. Confirm that value against the electrical drawings before ordering.
Does this Running Man sign include battery backup?
Yes. The S900RM series includes a maintenance-free NiMH battery for 90-minute emergency operation after a full charge.
Which pictogram directions are included?
The pictogram set supports no-arrow, left-arrow, right-arrow, and blank panel setup so the installer can match the final egress route.
Can S900RM be used outdoors?
S900RM is intended for protected indoor damp-location use. Use a wet-location exit sign for exposed exterior, spray, or washdown areas.
When should I choose S900RM instead of a text EXIT sign?
Choose it when the plans call for symbol-based egress signage or when a cleaner acrylic presentation is preferred for finished commercial interiors.