Low-Profile Wet-Location LED Combo Exit Sign

SKU: WLCEM1RGW
Regular price $181.35

Got questions?

Give us a call 800-847-1955!

Low-Profile Wet-Location LED Combo Exit Sign

The WLCEM Low‑Profile Wet‑Location Exit / Emergency Combo delivers dependable egress lighting in harsh, damp, or hose‑down environments. A gasket‑sealed polycarbonate housing protects dual 1 W LED lampheads and a field‑selectable red or green LED EXIT legend. Tool‑friendly mounting, a 90‑minute Ni‑Cd backup, and optional RC 2 W remote capacity or cold‑weather package make code compliance straightforward. Explore our wet‑location exit sign combos , exit sign & emergency light combos , low‑profile exit signs , and—for classified sites— hazardous‑location exit sign & light combos .

Specs, documents, buying checks, accessories, and FAQs are organized below from product fields for easier review.

Buying support

Product details and buying checks

Review specs, documents, buying checks, compatible products, and FAQs before ordering.

  • UL 924
  • Red / Green
  • Dual 1 W Heads
  • 120/277 VAC
  • Ni‑Cd / 90 min
  • Wet Location
  • Polycarbonate
  • Remote 2 W (Opt.)
  • Cold Weather (Opt.)
  • Low Profile

Key features

  • UL 924 wet‑location listing ( 0–50 °C ) for wash‑down / outdoor exposure
  • Gasketed, impact‑resistant polycarbonate housing with clear sealed lens
  • Dual 1 W LED heads; design‑aid spacing up to 18 ft at 7.5 ft mounting height
  • Field‑selectable EXIT legend: red or green ; snap‑out chevrons for wayfinding
  • Universal 120/277 VAC input; status LED & push‑to‑test for code checks
  • 3.6 V Ni‑Cd battery with ≥ 90 min runtime; solid‑state transfer; two‑rate charger (~ 24 h )
  • Mounting: snap‑fit canopy ( top/end ) + universal backplate for wall / conduit ; standard J‑box pattern
  • Options: CW cold‑weather to −20 °C ; RC 2 W remote capacity (see compatible remote LED heads ); TP tamper‑resistant kit
  • Compliance: NFPA 101 , NEC , OSHA ; CEC Title 20
  • Warranty: 5‑year electronics/housing; battery 5‑year prorated
Product family Exit Sign / Emergency Light Combos
SKU WLCEM1RGW
Listing UL 924
Environment outdoor exposure
Power led lens

Documents

Related Wet‑Location Combo Guides

Wet‑Location Emergency Lighting — NEMA 4X/IP65/IP66 & Gasketed Enclosures Exit/Emergency Combos — Code Triggers, Mounting & Sizing

Spec Sheet

Download WLCEM Exit Combo Spec Sheet (PDF)

Illumination
  • Two high‑output 1 W LED lampheads; design‑aid spacing up to 18 ft at 7.5 ft height
  • Field‑selectable red or green LED EXIT legend; chevrons included
Electrical
  • 120/277 VAC input with test button and bi‑color status LED
  • 3.6 V Ni‑Cd battery provides ≥ 90‑minute emergency runtime
  • Solid‑state transfer switch and two‑rate charger ( ~24‑hour recharge)
Mounting
  • Snap‑fit polycarbonate canopy for top or end mount
  • Universal backplate with knockouts for wall / conduit mounting; compatible with common J‑box layouts
  • Field‑selectable chevrons with snap‑out arrows
Housing / Lens
  • Impact‑resistant, UV‑stabilized polycarbonate housing (white, black, or gray)
  • Gasket‑sealed clear lens for outdoor‑rated exit sign combos
Options
  • CW — cold‑weather battery (operates down to −20 °C )
  • RC — 2 W remote‑head capacity
  • TP — tamper‑resistant hardware kit
Warranty / Listings
  • 5‑year warranty on electronics & housing; battery prorated 5 years
  • Listed to UL 924 for wet locations ( 0 °C – 50 °C )
  • NFPA 101 , NEC , OSHA , and CEC Title 20 compliant
Dimensions
  • See spec sheet for detailed dimensions and knockout locations
Compliance notes
  • Confirm final fixture placement, runtime, and local AHJ acceptance for the project.
  • Verify the selected model is rated for the final environment before ordering.