Photoluminescent Exit Sign - Indoor, 100 Ft Viewing, Non-Electrical, Single or Double Sided - Features & Specs

This indoor 100-ft photoluminescent exit sign is built for long interior sightlines—think large lobbies, straight corridors, atriums, and warehouse aisles—where a listed 100-foot viewing distance is required. It provides UL 924 code-ready visibility with no power, wiring, or batteries. Offered in single- or double-sided versions with red or green letters. For a tritium-based non-electrical alternative, see our self-luminous exit signs. Browse all photoluminescent exit signs.

100 Ft Viewing No Power Needed UL 924 Listed Single/Double Face

Key Features

  • Interior 100-ft classification: UL 924 listed for long, straight indoor approaches
  • Non-electrical, non-radioactive: no wiring, batteries, or bulbs—zero energy cost
  • Single or double face; red or green EXIT legend; chevrons included
  • Universal mounting hardware for wall, flag, and ceiling installations
  • Lightweight construction for fast retrofit and new construction installs
  • No Power Needed
  • Zero Maintenance
  • 100 Ft Viewing
  • Glow-in-the-Dark

Frequently Purchased With:

These compatible mounting brackets and installation hardware.

Framed Photoluminescent Exit Signs Mounting Brackets
Mounting Brackets

1.5', 10', 19.5' for Framed Photoluminescent Exit Signs

Photoluminescent Mounting Hardware Kit
Mounting Hardware

Wall, ceiling, and flag mounting hardware for photoluminescent signs

Illumination

  • Charged by ambient LED, fluorescent, mercury vapor, or metal halide lighting
  • Requires ≥ 5 foot-candles (54 lux) on the face during occupancy
  • Photoluminescent material provides automatic visibility during outages

Electrical

  • No electricity required – 100% non-powered operation
  • No batteries, wiring, or circuit connections
  • Zero routine maintenance after installation

Mounting

  • Universal hardware included
  • Supports surface wall, flag, and ceiling installations
  • Chevron arrows can be applied or left blank as needed

Housing / Finish

  • Impact-resistant plastic frame with photoluminescent substrate and high-contrast EXIT legend
  • Dimensions: 15.5" W × 8.75" H × 0.75" D
  • Lightweight design for fast installation

Options

  • Face Type – Choose single- or double-sided
  • Letter Color – Red or green EXIT legend

Warranty / Listings

  • UL 924 listed; compliant with IBC/IFC and NFPA 101 Life Safety Code
  • OSHA 1910.37(b)(6) wayfinding compliant
  • Viewing distance: 100 ft when properly charged

Frequently Asked Questions

Which interior scenarios typically call for a 100-ft viewing classification?

Large lobbies, long straight corridors, gymnasiums, atriums, and warehouse aisles where the approach distance to the sign can exceed 50 ft. If staff or the public must identify an exit across a long interior span, the 100-ft classification helps keep the legend legible at that range.

How do I verify on-site that this sign is adequately charged before a final inspection?

Use a lux meter to confirm ≥ 5 fc (54 lux) on the sign face during occupied hours. Record the reading, then confirm legibility from the intended approach distance (up to 100 ft) with normal lighting conditions and again during a lights-out drill after a full charge period.

Will protective glazing, acrylic shields, or tinted films reduce performance indoors?

Yes—tinted or UV-filtering covers can cut charging light reaching the photoluminescent panel. If a shield is required, use clear, non-tinted material and re-check the face illumination to maintain ≥ 5 fc.

What interior wall and paint colors improve 100-ft readability?

High contrast behind the legend improves recognition at distance. For red letters, light neutral walls typically help. For green letters, medium-to-dark neutrals often increase contrast. Avoid patterned or highly reflective backgrounds immediately behind the sign.

How should I place 100-ft signs along long corridors with turns and intersections?

Position a sign so the legend is visible from each decision point. Before a change in direction, place a sign that is clearly readable along the approaching line-of-sight, then another after the turn to confirm the new path.

Do interior dimming schedules or vacancy/Daylight sensors affect this model’s performance?

They can. If lights dim or shut off during occupancy, the face may not receive ≥ 5 fc and the legend can underperform at 100 ft. Coordinate controls so the egress lighting serving the sign maintains required illumination whenever the area is occupied.

Can I locate this sign behind glass (vestibules, display cases) and rely on daylight only?

Not recommended. Daylight varies and may be absent during evening occupancy. Provide electric ambient lighting on the sign face to maintain ≥ 5 fc during all occupied periods.

What commissioning checklist should I keep for the AHJ for this 100-ft indoor model?

Keep the product data showing the 100-ft UL 924 classification, the installation location, mounting method, legend color/face configuration, and recorded face-illuminance readings (lux/fc). Note any controls affecting local lighting and the date/time of your verification.

Related Categories