Remote-Capable LED Exit Sign - Field-Selectable Red/Green
Couldn't load pickup availability
Got questions?
Give us a call 800-847-1955!
Remote-Capable Thermoplastic LED Exit Sign — 3.0 W Remote Output, Red/Green Legend, Ni-Cd 90 min, 120/277 V — Features & Specs
The CEXTEU Remote-Capable LED Exit Sign delivers bright, code-legible wayfinding in a compact, flame-rated thermoplastic cabinet with the flexibility of 3.0 W remote-head output. A universal backplate and EZ-snap canopy simplify wall, top, or end mounting, while the 3.6 V Ni-Cd pack supplies 90-minute emergency operation. Select a red or green legend, add SDT self-testing for automated diagnostics, or choose SPV 120/230 V for international mains. For related choices, see our exit signs with built-in remote output.
Key Features
- UL 924 listed exit sign; damp-location rated (0–40 °C / 32–104 °F).
- Field-selectable red or green legend; ships single-face with field conversion to double-face.
- Remote-capable output up to 3.0 W to power compatible remote heads.
- 3.6 V Ni-Cd battery with 90-minute emergency runtime; two-rate charger (~24 h recharge).
- Universal 120/277 V input; optional SPV 120/230 V for international services.
- Bi-color status LED (normal/fault) and push-to-test; solid-state transfer driver.
- UL 94 5VA flame-rated thermoplastic housing (white or black); snap-out chevrons.
- Options: SDT self-testing diagnostics; SPV special-voltage input.
- 5-year warranty on electronics & housing; battery 5-year prorated; CEC Title 20 compliant.
Applications & Design Notes
Choose CEXTEU when you need a slim, economical exit sign that can extend egress illumination a few feet beyond the doorway or around a corner. Typical placements include elevator lobbies, intersecting corridors, small vestibules, and stair landings with a “dead-spot” just off the threshold. The 3.0 W remote budget supports a single higher-output remote or two ultra-compact heads—ideal when a full combo is excessive but a standalone emergency light would clutter the wall.
Plan remote loads by sum of head watts. Keep total = 3.0 W and size conductors to curb voltage drop on longer runs. Where bid specs call for uniform signage, match legend color to the floor standard, select double-face where approach occurs from both directions, and set chevrons during rough-in to lock directionality. If the project requires heavier abuse resistance or jurisdictional particulars, a steel exit sign or a Chicago-approved model is often the right alternate.
Related Remote-Capable Guides
Spec Sheet
Download CEXTEU Remote-Capable Exit Sign Spec Sheet (PDF)
Specifications (Overview)
- Legend: Red or green EXIT; single-face (field-convertible to double-face); snap-out chevrons.
- Remote Output: up to 3.0 W (RC) for compatible remote heads.
- Listings: UL 924 emergency signage; damp-location rated (0–40 °C).
- Housing: UL 94 5VA thermoplastic; white or black finish.
Illumination
- Long-life LEDs provide uniform legend visibility with high contrast in smoke-dimmed conditions.
- Use the RC budget to power adjacent remote heads where extra egress light is needed beyond the sign’s face visibility.
Electrical
- Dual-voltage 120/277 V input; optional SPV 120/230 V model (50/60 Hz).
- 3.6 V Ni-Cd battery; 90-minute emergency operation; solid-state transfer.
- Two-rate automatic charger restores full capacity in approximately 24 hours.
- Bi-color status LED (green = normal / red = service) and push-to-test for fast checks.
- RC output: 3.0 W total—size heads and wiring to remain within budget and limit voltage drop.
Mounting
- Top/End: EZ-snap canopy mates to standard J-box patterns.
- Wall: universal knockout backplate supports surface mount without special adapters.
Housing / Finish
- Injection-molded, impact-resistant UL 94 5VA thermoplastic for a lightweight yet durable enclosure.
- Finish options: white or black to coordinate with interior palettes.
Options
- SDT — self-testing diagnostics (monthly / semi-annual / annual) for automated compliance logs; see self-diagnostic exit signage.
- SPV 120/230 V — special-voltage input for facilities on 230 V mains (maintains listing without field transformers).
- Pair with compatible LED remote heads sized to the 3.0 W RC budget.
Certifications / Warranty
- UL 924 listed; damp-location rating (0–40 °C).
- Meets NFPA 101, NEC, and OSHA; CEC Title 20 compliant.
- 5-year warranty on electronics & housing; Ni-Cd battery 5-year prorated.
Dimensions
- Refer to the spec sheet drawings for envelope dimensions, faceplate, and canopy details.
Installation & Code Tips
- Arrow setup: Set chevrons to match the approved egress direction; document left/right/double in submittals.
- RC budgeting: Sum the rated watts per head; keep the total = 3.0 W. Shorter runs and appropriate wire gauge help minimize voltage drop.
- Testing cadence: Allow a full charge before performing the initial 90-minute discharge. Log monthly functional checks and annual full-duration tests.
- Face selection: Use double-face where occupants approach from both directions (e.g., at corridor intersections).
- International mains: Specify SPV 120/230 V to maintain listing without a step-down transformer.
Compare Remote-Output EXIT Signs by Budget Tier & Housing
RC-only exit signs contrasted by remote watts, legend configuration, input options, and housing style (no pricing).
| Model (H1) | Remote Budget | Legend / Faces | Mount Options | Input Choices | Diagnostics | Housing Style | When to Choose |
|---|---|---|---|---|---|---|---|
| This model — CEXTEU remote-capable LED exit sign | 3.0 W RC | Red/Green; single ? double (field) | Wall · Top/End canopy | 120/277 V; SPV 120/230 V opt. | SDT (optional) | Thermoplastic, slim | Small “dark pockets” near doors; budget retrofits |
| Remote-output exit sign — 5.5 W class (CEMXTE) | 5.5 W RC | Red/Green; single/double | Wall · Top/End canopy | 120/277 V; SPV opt. | SDT (optional) | Thermoplastic, low-profile | Longer remote throws; two-head remote runs |
| Chicago steel EXIT/STAIR — non-RC baseline (CAXTE) | — (not RC) | 6" red; single/double | Wall · Top/End steel canopy | 120/277 V | — | Steel, rugged | AHJ/Chicago jobs; heavier-duty interiors |
| Edge-lit EXIT/STAIR — architectural, non-RC | — (not RC) | 8" red; single/double | Surface canopy (edge-lit) | 120/277 V | — | Aluminum, edge-lit | Architectural corridors; aesthetic priority |
Frequently Asked Questions
What does “remote-capable” mean for the CEXTEU?It means the internal battery/driver can power external remote heads up to a total of 3.0 W. Use this to illuminate a nearby alcove, vestibule, or short corridor segment without adding a full combo unit.
How do I size remote heads to the 3.0 W budget?Check each head’s rated watts and sum the load. Keep the total = 3.0 W. Use shorter runs and appropriate wire gauge to minimize voltage drop and maintain performance.
Can I run on 230 V mains?Yes—specify the SPV 120/230 V model to maintain listing and avoid external step-down transformers.
Is self-testing available?Yes. The SDT option automates monthly, semi-annual, and annual tests with status indication for maintenance logs and audits.
When should I choose double-face?Use double-face where occupants approach from both directions (e.g., corridor intersections); otherwise single-face reduces load and visual clutter.
- remote-capable exit sign 3.0 W
- thermoplastic LED exit signage
- Ni-Cd 90-minute UL 924 sign
- self-diagnostic exit sign SDT
- SPV 120/230 V special-voltage input
Buying support
Product details and buying checks
Review specs, documents, buying checks, compatible products, and FAQs before ordering.
- UL 924
- LED Legend
- Ni‑Cd / 90 min
- 120/277 V
- Remote 3.0 W
- Self‑Testing (Opt.)
- Red / Green
- Damp Location
- NFPA 101
- OSHA
Key features
- UL 924 listed exit sign; damp‑location rated ( 0–40 °C / 32–104 °F ).
- Field‑selectable red or green legend; ships single‑face with field conversion to double‑face .
- Remote‑capable output up to 3.0 W to power compatible remote heads.
- 3.6 V Ni‑Cd battery with 90‑minute emergency runtime; two‑rate charger (~ 24 h recharge).
- Universal 120/277 V input; optional SPV 120/230 V for international services.
- Bi‑color status LED (normal/fault) and push‑to‑test; solid‑state transfer driver.
- UL 94 5VA flame‑rated thermoplastic housing (white or black); snap‑out chevrons.
- Options: SDT self‑testing diagnostics; SPV special‑voltage input.
- 5‑year warranty on electronics & housing; battery 5‑year prorated; CEC Title 20 compliant.
Documents
Applications & Design Notes
Use CEXTEU for indoor commercial egress routes that need a compact UL 924 exit sign with battery backup and optional low-wattage remote-head capacity. Good fits include elevator lobbies, intersecting corridors, small vestibules, stair landings, and doorway areas where the EXIT legend handles wayfinding and a nearby remote head can cover a small dark spot. This is a thermoplastic, damp-location exit sign for wall, ceiling, or end mounting; it is not a steel or wet-location exit sign. Keep connected remote load at or below the 3.0 W RC budget, match red or green legend color to project/AHJ requirements, choose single- or double-face configuration based on approach direction, and set chevrons during rough-in.
- Best fit: indoor/damp commercial exit signage with optional nearby remote-head coverage.
- Avoid using as a wet-location, outdoor, vandal-resistant, or steel-exit-sign substitute.
- Remote output: keep compatible remote heads within the 3.0 W budget and account for voltage drop.
Related Remote‑Capable Guides
Remote Heads — Sizing, Wiring & Voltage‑Drop (Calculator) Self‑Testing Exit Signs — Benefits & Compliance
Spec Sheet
Download CEXTEU Remote‑Capable Exit Sign Spec Sheet (PDF)
Specifications (Overview)
- Legend: Red or green EXIT; single‑face (field‑convertible to double‑face); snap‑out chevrons.
- Remote Output: up to 3.0 W (RC) for compatible remote heads.
- Listings: UL 924 emergency signage; damp‑location rated ( 0–40 °C ).
- Housing: UL 94 5VA thermoplastic; white or black finish.
Illumination
- Long‑life LEDs provide uniform legend visibility with high contrast in smoke‑dimmed conditions.
- Use the RC budget to power adjacent remote heads where extra egress light is needed beyond the sign’s face visibility.
Electrical
- Dual‑voltage 120/277 V input; optional SPV 120/230 V model (50/60 Hz).
- 3.6 V Ni‑Cd battery; 90‑minute emergency operation; solid‑state transfer .
- Two‑rate automatic charger restores full capacity in approximately 24 hours .
- Bi‑color status LED (green = normal / red = service) and push‑to‑test for fast checks.
- RC output: 3.0 W total—size heads and wiring to remain within budget and limit voltage drop.
Mounting
- Top/End: EZ‑snap canopy mates to standard J‑box patterns.
- Wall: universal knockout backplate supports surface mount without special adapters.
Housing / Finish
- Injection‑molded, impact‑resistant UL 94 5VA thermoplastic for a lightweight yet durable enclosure.
- Finish options: white or black to coordinate with interior palettes.
Options
- SDT — self‑testing diagnostics (monthly / semi‑annual / annual) for automated compliance logs; see self‑diagnostic exit signage .
- SPV 120/230 V — special‑voltage input for facilities on 230 V mains (maintains listing without field transformers).
- Pair with compatible LED remote heads sized to the 3.0 W RC budget.
Certifications / Warranty
- UL 924 listed; damp‑location rating ( 0–40 °C ).
- Meets NFPA 101 , NEC , and OSHA ; CEC Title 20 compliant.
- 5‑year warranty on electronics & housing; Ni‑Cd battery 5‑year prorated .
Compliance notes
- Confirm final fixture placement, runtime, and local AHJ acceptance for the project.