Slim Thermoplastic LED Exit Sign with Universal Face Configuration
Couldn't load pickup availability
Got questions?
Give us a call 1-888-959-1965!
Slim Thermoplastic LED Exit Sign - Red/Green Universal Face
The ETXTEU slim thermoplastic LED exit sign gives contractors a compact, code-ready EXIT sign for standard commercial egress routes. Use it where a low-profile thermoplastic housing, selectable red or green LED legend, and universal single/double-face setup help simplify ordering and installation. Optional battery-backup models add UL 924 90-minute emergency operation while standard AC-only models keep the same clean footprint for projects that do not require integral backup.
Need a slim thermoplastic exit sign for a standard doorway? This LED thermoplastic exit sign is a low-profile, universal-face option for commercial egress paths that need simple wall, ceiling, or end mounting with dependable 90-minute emergency backup. Use this product when the job calls for a clean thermoplastic housing, field-configurable face direction, and standard EXIT visibility without a steel or edge-lit housing. Compare the full Thermoplastic Exit Signs category, browse all Exit Signs, or review the Thermoplastic Exit Signs guide before choosing the final model.
The series supports 120/277 VAC input, white or black housing, snap-out directional chevrons, top/end/wall mounting, and damp-location use from 0-50 C. For nearby buying paths, compare all thermoplastic exit signs, review edge-lit exit signs for architectural panels, or choose an exit sign and emergency light combo when the doorway also needs adjustable lamp heads.
Specs, documents, buying checks, accessories, and FAQs are organized below from product fields for easier review.
Buying support
Product details and buying checks
Review specs, documents, buying checks, compatible products, and FAQs before ordering.
- UL 924
- Red / Green Legend
- Single / Double Face
- Optional Ni-Cd / 90 min
- 120/277V
- Low Profile
- Universal Mount
- Damp Location
- Thermoplastic 5VA
- NFPA 101
- OSHA
Key features
- UL 924 listed LED exit sign for code-required egress marking in standard commercial interiors.
- Field-selectable red or green LED legend helps match building plans, local preference, or existing building signage.
- Universal single/double-face kit with snap-out chevrons supports left, right, or bi-directional exit routing.
- Dual-voltage 120/277 VAC input with status LED and push-to-test for quick commissioning and routine checks.
- Optional EM versions include a maintenance-free Ni-Cd battery with minimum 90-minute emergency runtime.
- Solid-state transfer, low-voltage disconnect, brownout protection, and two-rate charger support reliable battery operation.
- EZ-snap canopy supports top or end mounting; universal backplate supports surface wall mounting.
- Slim 5VA flame-retardant thermoplastic housing is available in white or black for low-profile interiors.
- Damp-location rated from 0-50 C for suitable interior or covered applications.
- 5-year limited warranty on electronics and housing; battery coverage is 5-year prorated.
Documents
Where the ETXTEU Fits Best
Choose ETXTEU when a project needs a compact thermoplastic LED exit sign with flexible legend color, face count, and mounting. It is a practical choice for tenant improvements, office corridors, small retail suites, schools, light industrial hallways, hospitality back-of-house areas, and multi-family common spaces.
Red/Green Legend and Face Setup
- Select red or green to match the building plans, local code interpretation, or the color already used on the floor.
- Use single-face setup when the sign is viewed from one direction, such as above a doorway or at the end of a corridor.
- Use double-face setup at intersections or open corridors where the EXIT legend must be visible from both approaches.
- Snap-out chevrons support left, right, and bi-directional routing without ordering separate arrow plates.
Electrical and Battery Backup
- Universal 120/277 VAC input supports common commercial branch circuits.
- Status LED and push-to-test support monthly functional checks and annual 90-minute battery tests.
- EM models include a maintenance-free Ni-Cd battery for a minimum 90-minute emergency runtime per UL 924.
- Solid-state transfer, brownout protection, low-voltage disconnect, and two-rate charging support dependable emergency operation.
- Allow a full charge cycle before performing a full-duration discharge test after installation.
Mounting
- Top mount or end mount with the included EZ-snap canopy where the fixture needs to hang from or beside the junction box.
- Wall mount with the universal backplate and knockouts for common surface installations.
- Lightweight thermoplastic construction helps installers position the sign quickly on ladders or lifts.
- Confirm final mounting height, spacing, and sightline requirements with the project plans and local code official.
Housing / Finish
- Slim thermoplastic housing reduces projection into narrow corridors and door-header locations.
- 5VA flame-retardant construction supports common commercial life-safety specifications.
- White housing blends with most walls and ceilings; black housing can suit darker finishes or contrast-driven designs.
- Tool-less face changes help crews adapt from single to double face on site.
Installation and Code Tips
- Keep EXIT legends visible from the direction of travel and avoid obstructions from doors, soffits, or ceiling features.
- Document push-to-test checks and annual full-duration tests for closeout and maintenance records.
- For damp-location areas such as covered entries, confirm ambient conditions remain within 0-50 C.
- For exposed outdoor, hose-down, or harsh applications, compare wet-location exit signs instead of using a standard damp-location unit.
- If the project calls for NYC-specific construction, confirm the listing and legend requirements before substituting.
Compare Similar Exit Sign Options
Use ETXTEU for a slim, economical thermoplastic LED exit sign with red/green selection and universal face setup.
- Low-profile red/green universal-mount exit sign: choose when a DIP-switch red/green toggle and alternate low-profile housing better match the spec.
- Edge-lit thermoplastic exit sign: choose when the public-facing area needs an acrylic panel and more architectural appearance.
- Exit sign and emergency light combo: choose when the same doorway also needs adjustable emergency lamp heads.
- Wet-location exit sign: choose for exposed exterior or washdown conditions beyond standard damp-location use.
Certifications / Warranty
- UL 924 listed for exit signage and emergency operation where configured with battery backup.
- Damp-location rated from 0-50 C.
- Designed to support NFPA 101, NEC, OSHA, and CEC Title 20 requirements where applicable.
- 5-year limited warranty on electronics and housing; battery coverage is 5-year prorated.
Related Exit Sign Guides
- UL 924 Compliance Guide
- Exit Signs 101 - Code, Colors, Faces, and Power Options
- Exit Sign & Emergency Light Combos - When to Specify a Combo
Compliance notes
- Confirm final fixture placement, legend color, battery-backup requirement, and local code approval for the project.
Frequently asked questions
Can I choose between red or green LED legends?
Yes. ETXTEU supports a field-selectable red or green EXIT legend, so the installer can match building plans, owner preference, or existing signage.
Is this exit sign single face or double face?
Both. It ships with a universal single/double-face setup and snap-out directional chevrons for left, right, or bi-directional routing.
Does every ETXTEU model include battery backup?
No. Battery backup is optional. Choose an EM variant when the fixture needs 90-minute emergency operation during a power loss.
How long does the emergency battery run?
EM versions provide a minimum 90-minute emergency runtime per UL 924 after the battery has completed a full charge cycle.
Can this slim thermoplastic exit sign be wall, ceiling, or end mounted?
Yes. The universal backplate supports wall mounting, and the EZ-snap canopy supports top or end mounting to common junction-box locations.
Is this model suitable for damp locations?
Yes, it is damp-location rated from 0-50 C. For exposed outdoor, hose-down, or harsh environments, use a wet-location exit sign instead.
What options are included in this product family?
Current variants include ETXTEU3RW, ETXTEU3RWEM, ETXTEU3RB, ETXTEU3RBEM, ETXTEU3GW, ETXTEU3GWEM, ETXTEU3GB, and ETXTEU3GBEM.