Flush-Mount LED Emergency Light – Adjustable Dual Head, Concealed Hinged Doors

SKU: S-NC-18-2
Regular price $1,144.64

Got questions?

Give us a call 800-847-1955!

Stealth Flush-Mount LED Emergency Unit — Dual 9 W MR-16 Heads, 120-min Runtime, Hinged Doors — Features & Specs

The Stealth Flush-Mount LED Emergency Lighting Unit hides two fully adjustable 9 W MR-16 LED heads behind paintable doors that sit flush to the ceiling or wall. When AC power fails, the spring/solenoid doors open instantly to deliver bright, uniform egress lighting; when power is restored, they retract automatically. A maintenance-free battery provides up to 120 minutes of emergency runtime.

UL 924 120/277 VAC 120-min Battery MR-16 LED Flush / Recessed Wall or Ceiling G2 Self-Test Damp Location (opt.) BAA/BABA

Key Features

  • Doors sit flush to the surface and can be painted, textured, or wallpapered for a near-invisible look in normal mode.
  • Automatic spring/solenoid mechanism with magnetic latch opens on power loss and retracts on restore for silent, reliable operation.
  • Dual 9 W MR-16 LED heads (independently adjustable) with metallized reflectors for uniform egress coverage; lamp life to 60,000 hours.
  • Up to 120 minutes of emergency runtime; typical 24-hour recharge.
  • Guardian™ G2 self-test / diagnostics standard with multicolor status LED.
  • 120/277 VAC dual-voltage input; Ni-Cd or sealed lead-calcium battery options.
  • Universal wall or ceiling installation; rough-in opening 6" × 9".
  • Galvanized steel back-box with aluminum doors/lamp housing; finish white (custom colors available).
  • Options/accessories: DR (Damp Location), CC (Custom Color), RTP (Remote Test Panel), retrofit kit for legacy housings.

Related Recessed & Self-Testing Guides

Spec Sheet

Download Stealth Flush-Mount Emergency Unit Spec Sheet (PDF)

Illumination

  • Two 9 W MR-16 LED heads; independently adjustable for precise aiming.
  • Door interiors feature reflective surfaces to maximize delivered light.

Electrical

  • Dual-voltage 120/277 VAC input, 60 Hz; solid-state charging circuit.
  • Maintenance-free Ni-Cd or sealed lead-calcium battery; 120-minute emergency run, ~24-hour recharge.
  • Guardian™ G2 self-test/diagnostics standard (monitors AC, battery, charger, transfer, and lamp circuits).

Mounting

  • Flush mount in ceilings or walls; fits standard 6" × 9" rough opening.
  • Magnetic-latch doors adjustable through 90°; surface-mount kit available.

Housing / Finish

  • Galvanized-steel back-box with aluminum doors and lamp housing.
  • Finish: White (custom colors available via CC option).
  • Option DR: Damp-location rated.

Dimensions

  • Back-box: 10" W × 7" H × 4" D; required opening: 6" H × 9" W.

Warranty / Listings

  • 3-year warranty on electronics & housing; battery 3-year prorated.
  • cETLus listed to UL 924; meets NFPA 101 & NEC; BAA/BABA compliant.

Buying support

Product details and buying checks

Review specs, documents, buying checks, compatible products, and FAQs before ordering.

  • UL 924
  • 120/277 VAC
  • 120-min Battery
  • MR-16 LED
  • Flush / Recessed
  • Wall or Ceiling
  • G2 Self-Test
  • Damp Location (opt.)
  • BAA/BABA
  • NFPA 101

Key features

  • Doors sit flush to the surface and can be painted, textured, or wallpapered for a near-invisible look in normal mode.
  • Automatic spring/solenoid mechanism with magnetic latch opens on power loss and retracts on restore for silent, reliable operation.
  • Dual 9 W MR-16 LED heads (independently adjustable) with metallized reflectors for uniform egress coverage; lamp life to 60,000 hours .
  • Up to 120 minutes of emergency runtime; typical 24-hour recharge.
  • Guardian™ G2 self-test / diagnostics standard with multicolor status LED.
  • 120/277 VAC dual-voltage input; Ni-Cd or sealed lead-calcium battery options.
  • Universal wall or ceiling installation; rough-in opening 6" × 9" .
  • Galvanized steel back-box with aluminum doors/lamp housing; finish white (custom colors available).
  • Options/accessories: DR (Damp Location), CC (Custom Color), RTP (Remote Test Panel), retrofit kit for legacy housings.
Product family Emergency Lights
SKU S-NC-18-2
Listing UL 924
Runtime/service 120 minutes of emergency runtime; typical 24-hour recharge
Environment Damp Location), CC (Custom Color), RTP (Remote Test Panel), retrofit kit for legacy housings
Power LED heads (independently adjustable) with metallized reflectors for uniform egress coverage; lamp life to 60,000 hours

Documents

Related Recessed & Self-Testing Guides

Automatic-Testing Emergency Lights—UL 924 Monthly/Annual Checks

Spec Sheet

Download Stealth Flush-Mount Emergency Unit Spec Sheet (PDF)

Illumination
  • Two 9 W MR-16 LED heads; independently adjustable for precise aiming.
  • Door interiors feature reflective surfaces to maximize delivered light.
Electrical
  • Dual-voltage 120/277 VAC input, 60 Hz; solid-state charging circuit.
  • Maintenance-free Ni-Cd or sealed lead-calcium battery; 120-minute emergency run, ~ 24-hour recharge.
  • Guardian™ G2 self-test/diagnostics standard (monitors AC, battery, charger, transfer, and lamp circuits).
Mounting
  • Flush mount in ceilings or walls; fits standard 6" × 9" rough opening.
  • Magnetic-latch doors adjustable through 90° ; surface-mount kit available.
Housing / Finish
  • Galvanized-steel back-box with aluminum doors and lamp housing.
  • Finish: White (custom colors available via CC option).
  • Option DR : Damp-location rated.
Dimensions
  • Back-box: 10" W × 7" H × 4" D; required opening: 6" H × 9" W.
Warranty / Listings
  • 3-year warranty on electronics & housing; battery 3-year prorated .
  • cETLus listed to UL 924 ; meets NFPA 101 & NEC ; BAA/BABA compliant.
Compliance notes
  • Confirm final fixture placement, runtime, and local AHJ acceptance for the project.