LED-95 Thermoplastic LED Emergency Light - Dual 1.5W Heads
Couldn't load pickup availability
Got questions?
Give us a call 800-847-1955!
LED-95 Thermoplastic LED Emergency Light Overview
The LED-95 thermoplastic LED emergency light is a low-profile commercial egress fixture with dual 1.5W adjustable heads, a 90-minute Ni-Cd battery, and a compact flame-retardant housing. It is built for offices, retail corridors, tenant improvements, schools, healthcare support spaces, and other protected interiors that need a cost-effective commercial emergency light with stronger configuration depth than a basic two-head unit.
Choose white or black housing, add Guardian G2 self-test for automated diagnostics, or select the R remote-capable option when the fixture needs 3.4W of remote load capacity for one RL52 or up to two MLED remote heads. The LED-95 supports 120/277 VAC input, wall or ceiling orientation, tool-less access, damp-location use from 0-40 C, cULus 924 listing, CEC compliance context, and NFPA 101 / NEC review when matched to the project documents.
Compare thermoplastic emergency lights, use remote-capable emergency lights when remote heads are required, or review self-testing emergency lights when inspection workflow is the lead requirement. The structured fields below keep exact specs, documents, related guides, buying checks, and FAQs in separate roles so this page does not repeat the same sections.
Specs, documents, buying checks, related paths, and FAQs are organized below for easier review.
Buying support
Product details and buying checks
Before ordering LED-95, confirm finish, G2 diagnostics, R remote output, connected load, spacing, environment, and AHJ acceptance.
- LED-95 Series
- cULus 924
- CEC Compliant
- Damp Location
- Dual 1.5W Heads
- 25 ft Spacing Guide
- 90-min Ni-Cd
- 120/277V
- Remote-Capable R
- 3.4W Remote Capacity
- G2 Self-Test
- UL 94 V-0
- Tool-Less Access
- White / Black
- Wall / Ceiling
Key features
- LED-95 thermoplastic LED emergency light for commercial egress paths, tenant improvements, corridors, and facility maintenance replacements.
- Two fully adjustable 1.5W LED lamp heads support focused path-of-egress aiming after installation.
- Spacing guidance is up to 25 ft on center on a 3 ft path at 7.5 ft installed height, or about 20 ft on a 6 ft path.
- Ni-Cd battery provides 90-minute emergency runtime with typical 24-hour recharge after discharge testing.
- R variants add 3.4W remote capacity for one RL52 remote head or up to two MLED remote heads.
- R variants can run up to 180 minutes in emergency mode when no remote load is connected, per the manufacturer data.
- Guardian G2 self-test / self-diagnostics is available for automated monthly and annual testing with visual status indication.
- 120/277 VAC input, solid-state transfer, brownout protection, and low-voltage disconnect support commercial electrical requirements.
- UV-stable UL 94 V-0 flame-retardant thermoplastic housing is available in white or black finish.
- Tool-less housing access and universal J-box pattern help simplify field service and replacement work.
- Damp-location rating from 0-40 C supports protected indoor applications.
- cULus 924 listing, NFPA 101 / NEC context, and CEC compliance notes support project review.
Documents
Project Fit Checks
Use LED-95 when the project needs an economical, low-profile thermoplastic emergency light with adjustable LED heads, damp-location listing, and optional diagnostics or remote output in the same product family.
- Best fit: offices, retail interiors, schools, healthcare support areas, maintenance corridors, tenant improvements, and protected indoor egress routes.
- Good replacement path when the job needs a compact two-head emergency light with white or black housing choices.
- Review the LED-95 PDF before release so spacing, remote load, diagnostics, CEC note, and dimensional details are captured in the submittal.
Variant Review Path
Match the selected SKU to the housing color, diagnostic preference, and remote-head requirement shown on the drawings or maintenance request.
- Choose white or black finish to match the wall, ceiling, trim, or owner standard.
- Choose G2 when automated self-test diagnostics are required by the owner or maintenance program.
- Choose R when the fixture must power compatible low-voltage remote heads from its battery system.
- Choose G2-R only when both diagnostics and remote-head output are required on a white-housing unit.
Coverage and Remote Load Checks
Confirm the photometric layout and any connected remote heads before ordering, especially where corridors, turns, obstructions, or wider paths change the fixture count.
- Use the 25 ft and 20 ft spacing guidance as a planning reference, then confirm against project plans and final installed height.
- Remote-capable R versions provide 3.4W of remote capacity, not unlimited remote-head output.
- If no remote load is connected, R versions may provide longer emergency runtime than the standard 90-minute requirement.
When to Choose Another Unit
LED-95 is a protected-interior thermoplastic emergency light. Step to another product family when the environment, output, jurisdiction, or abuse risk changes.
- Use wet-location emergency lights for exterior, spray, washdown, or high-moisture spaces.
- Use higher-output emergency lights when fixture spacing or layout height exceeds the LED-95 capability.
- Use vandal-resistant or die-cast units for public areas exposed to impact or tampering.
- Use exit/emergency combo units when EXIT signage and emergency lighting heads are required at the same point.
Compliance notes
- Confirm housing color, G2 diagnostics, R remote-capable output, connected remote load, spacing, installed height, and AHJ acceptance before release.
- Use R versions only within the 3.4W remote capacity shown by the manufacturer; connected remote heads reduce available emergency runtime.
- LED-95 is damp-location rated for protected indoor use. Use a wet-location or vandal-resistant family where exposure or abuse risk exceeds this series.
- Manufacturer notes indicate G2 self-diagnostics are not CEC-listed even though standard LED-95 configurations are CEC compliant.
Frequently asked questions
Is LED-95 a thermoplastic LED emergency light with dual 1.5W heads?
Yes. LED-95 is a low-profile thermoplastic LED emergency light with two fully adjustable 1.5W lamp heads for commercial egress lighting.
Which LED-95 version is remote capable?
Select an R variant when the fixture must power compatible remote heads. R versions provide 3.4W remote capacity for one RL52 or up to two MLED remote heads.
What does G2 mean on this emergency light?
G2 is the Guardian self-test / self-diagnostics option. It supports automated monthly and annual testing with visual status indication. The manufacturer notes that the G2 option is not CEC-listed.
Does LED-95 provide 90-minute battery backup?
Yes. LED-95 uses a maintenance-free Ni-Cd battery for 90-minute emergency operation. The manufacturer data also notes that R versions can run 180 minutes when no remote load is connected.
Can LED-95 be used on wall or ceiling layouts?
Yes. The unit supports wall or ceiling orientation with a universal J-box pattern and rear keyholes. Confirm final aiming, spacing, and branch-circuit details before installation.
Is this emergency light suitable for wet outdoor locations?
No. LED-95 is damp-location rated for protected indoor use from 0-40 C. Use a wet-location emergency light for exposed exterior, spray, or washdown applications.
What finish colors are available?
The LED-95 family includes white and black housing options. Match the finish to the project schedule, wall color, or maintenance standard.