Edge-lit Exit Sign - Thermoplastic - Slim Profile
Couldn't load pickup availability
Got questions?
Give us a call 1-888-959-1965!
Slim Thermoplastic Edge-Lit LED Exit Sign Overview
This thermoplastic edge-lit LED exit sign pairs a crystal-clear acrylic panel with a slim 1.8" white housing to create a modern floating EXIT legend for UL 924 egress. Use it where an architectural-looking edge-lit panel is preferred over a standard direct-view thermoplastic exit sign, especially in offices, retail suites, hospitality corridors, lobby-adjacent spaces, schools, and other commercial interiors.
Need a thermoplastic edge-lit exit sign with a slim profile? This product combines thermoplastic exit sign durability with an edge-lit EXIT panel for spaces that need a cleaner architectural look than a standard box sign. Use it for corridors, offices, retail, hospitality, and tenant improvements where low-profile design, LED illumination, and 90-minute backup matter. Compare Edge-Lit Exit Signs, browse Thermoplastic Exit Signs, or read the Edge-Lit vs Thermoplastic Exit Signs guide before choosing the final product.
Universal hardware, field-selectable chevrons, and dual-voltage 120/277 V electronics support ceiling, end, or wall mounting out of the box. Choose single-face clear-panel configurations for one-way visibility, double-face mirror-panel configurations for corridors approached from both directions, red or green LED legends, and optional G2 self-diagnostics. Explore the full Edge-Lit Exit Signs lineup, compare Thermoplastic Exit Signs, or review UL 924 compliance guidance.
Specs, documents, buying checks, accessories, and FAQs are organized below from product fields for easier review.
Buying support
Product details and buying checks
Review specs, documents, buying checks, compatible products, and FAQs before ordering.
- UL 924
- Edge-Lit LED
- Thermoplastic
- UL 94 5VA
- Slim 1.8 in Profile
- 90-min Backup
- 120/277 V
- Red / Green Legend
- Single / Double Face
- Clear / Mirror Panel
- Universal Mount
- Damp Location
- CEC Title 20
- Self-Test Option
Key features
- Slim thermoplastic edge-lit LED exit sign with crystal-clear acrylic panel and floating EXIT legend.
- UL 924 listed for code-required egress signage, with 90-minute emergency runtime from a maintenance-free 4.8 V Ni-Cd battery.
- Dual-voltage 120/277 V, 60 Hz input supports common commercial electrical systems.
- Single-face models use a clear panel for one-direction viewing; double-face models use a mirror panel for two-direction corridor visibility.
- Red or green LED legends illuminate uniform 6-inch EXIT letters with long-life LEDs rated around 100,000 hours.
- Snap-fit canopy supports ceiling, end, or wall mounting, and field-selectable chevrons support left, right, or bi-directional routing.
- Slim 1.8-inch UL 94 5VA injection-molded thermoplastic housing resists denting and corrosion in standard interiors.
- UV-stabilized acrylic panel resists yellowing and scratches for clean presentation in public-facing spaces.
- Solid-state transfer, low-voltage disconnect, brownout protection, bi-color status LED, and push-to-test support routine maintenance.
- Optional G2 Guardian self-test/self-diagnostics helps automate monthly, semi-annual, and annual inspection checks.
- Damp-location rated and CEC Title 20 compliant for applicable commercial projects.
- 5-year warranty on electronics and housing; Ni-Cd battery coverage is 5-year prorated.
Documents
Best Applications
Choose this slim thermoplastic edge-lit exit sign for commercial interiors where a low-profile acrylic panel looks better than a standard direct-view fixture. Common applications include offices, retail suites, hotels, schools, clinics, multi-tenant corridors, reception-adjacent spaces, and other public-facing egress routes.
Face and Panel Selection
- Use single-face clear-panel configurations where people approach the sign from one direction, such as above a doorway or at the end of a corridor.
- Use double-face mirror-panel configurations at intersections or open corridors where the EXIT legend must be visible from two directions.
- Match red or green legend color to building plans, existing building signage, and local code preference.
- Set chevrons in the field so the arrows match the final direction of egress travel.
Electrical Runtime Checks
- Dual-primary 120/277 V input supports typical commercial branch circuits.
- A maintenance-free 4.8 V Ni-Cd battery provides 90 minutes of emergency operation after a full charge.
- Solid-state transfer, low-voltage disconnect, brownout protection, bi-color status LED, and push-to-test support reliable inspection routines.
- Allow the fixture to complete its recharge period before performing a full 90-minute discharge test after installation.
Mounting Orientation Checks
- Ceiling mount the sign where the egress path requires visibility from below or from a corridor approach.
- End mount the sign beside a wall or junction box when it must project perpendicular to the wall surface.
- Wall mount the sign above doors or path-of-travel points where one-direction visibility is sufficient.
- Confirm final mounting position, viewing distance, obstruction clearance, and local code approval before closeout.
G2 Diagnostics Decision
Choose the G2 self-test/self-diagnostics option when the owner wants automated monthly, semi-annual, and annual test support. Standard models still include a status LED and push-to-test button for manual checks.
Compare Similar Exit Sign Paths
- Choose edge-lit exit signs when the project needs an acrylic-panel, architectural appearance.
- Choose thermoplastic exit signs when budget and durable molded construction matter more than the edge-lit look.
- Choose recessed exit signs when the fixture must sit tighter to a finished ceiling or wall plane.
- Choose exit sign/emergency light combos when the same location also needs adjustable emergency lamp heads.
Closeout and Warranty Checks
- UL 924 listed for damp locations and designed to support NFPA 101, NEC, OSHA, and CEC Title 20 requirements where applicable.
- Final fixture placement, face count, arrow direction, and emergency lighting layout should follow building plans and local code requirements.
- 5-year warranty applies to electronics and housing; Ni-Cd battery coverage is 5-year prorated.
Compliance notes
- Confirm final fixture placement, face count, arrow direction, runtime, damp-location suitability, and local code approval for the project.
Frequently asked questions
Is this a UL 924 thermoplastic edge-lit LED exit sign?
Yes. The QXEDGP is a UL 924 listed thermoplastic edge-lit LED exit sign with battery backup for emergency egress signage.
Does this edge-lit exit sign include 90-minute battery backup?
Yes. The fixture includes a maintenance-free 4.8 V Ni-Cd battery that provides 90 minutes of emergency operation after a full charge.
Can this slim edge-lit exit sign be wall, ceiling, or end mounted?
Yes. The snap-fit canopy and universal hardware support ceiling, end, or wall mounting, so the same product family can cover common commercial installation orientations.
Should I choose a single-face clear panel or double-face mirror panel?
Use a single-face clear panel when the EXIT legend only needs to be read from one direction. Use a double-face mirror panel when the sign must be visible from two directions, such as a corridor intersection.
Is this model available with red or green EXIT letters?
Yes. The product family includes red and green LED letter configurations. Match the building plans, existing signage, and local code preference.
What does the G2 self-diagnostics option add?
The optional G2 Guardian self-test/self-diagnostics package automates routine test cycles and provides status reporting support for maintenance teams.
Is this edge-lit exit sign damp-location rated?
Yes. It is listed for damp locations. For exposed outdoor, washdown, or wet-location applications, compare wet-location exit signs instead.