Assembled in USA Exit Signs – LED, 90-Min Backup (UL 924)

Shop Assembled in USA exit signsUL 924 LED fixtures that keep the EXIT legend illuminated for at least 90 minutes during outages. Proudly assembled in the USA, these signs support fast lead times and rigorous quality standards. Explore all exit signs, compare battery backup exit signs, and see design-forward edge-lit exit signs. For tougher installs, browse steel exit signs or matte black exit signs.

UL 924 LED 90-Min Backup Assembled in USA Single/Double Face Universal Mount
Buyers Guide Tips

What to Look for in Assembled in USA Exit Signs

  • UL 924 Listing: Confirms 90-minute emergency runtime and egress performance.
  • Origin & Compliance: “Assembled in USA” ≠ “Made in USA.” Verify BAA/TAA or origin documentation if required.
  • Battery Chemistry: Ni-Cd, Li-ion, or LiFePO4; check recharge time, temp range, and cycle life.
  • Legend & Faces: Red/green letters, field-selectable chevrons, single/double-face options.
  • Self-Testing: Automated monthly/annual diagnostics to streamline inspections.
  • Mounting Flexibility: Universal wall/ceiling/end mounting; canopy included on many models.
  • Environment Rating: Damp/wet versions for humidity or wash-down; cold-weather kits where needed.
Why choose exit signs assembled in the USA? Tighter quality control, shorter lead times, and easier sourcing for public projects. If your job requires BAA/TAA or specific origin documentation, verify the exact model’s certifications in the submittal.

Choose budget-friendly thermoplastic or premium metal housings with clean architectural lines. Most models include field-selectable chevrons, single- or double-face panels, and universal wall/ceiling/end mounting to streamline installation. For corridor and center-hall applications, see double face exit signs; for standard wall locations, pick single face exit signs.

Integrated, maintenance-free batteries and solid-state charging/transfer circuits ensure dependable operation when mains power fails. Many USA-assembled models add self-testing diagnostics to automate monthly/annual checks and support NFPA 101 readiness.

For weather-exposed installs, choose wet-location exit signs. In harsh industrial settings, consider sealed NEMA-rated emergency lights for extra protection.

Listings, runtime, and features vary by model—confirm specifications and accessories on the product page.

Filter products

65 Products

Assembled in USA Exit Signs Spec Guide

Spec Snapshot

  • Compliance: UL 924 listed with a minimum 90-minute backup; supports NFPA 101 egress requirements.
  • Legend & Visibility: Red or green LED legend, 6–8 in letters, field-selectable chevrons; single- or double-face. Verify local codes (e.g., NYC 8" letters).
  • Battery Backup: Integrated Ni-Cd or lithium (Li-ion/LiFePO4) packs with solid-state charging/transfer.
  • Origin & Documentation: Assembled in USA; request submittals, certificate of assembly/origin, and any required BAA/BABA/TAA statements for funded projects.
  • Mounting & Housing: Universal wall/ceiling/end mount with canopy on many models; thermoplastic or metal housings with architectural finishes.
  • Environment & Options: Damp-location ratings common; specify wet-location or cold-weather packages as needed. Self-testing diagnostics available on select models.

FAQs About Assembled in USA Exit Signs

What does “Assembled in the USA” mean for exit signs?

Final assembly occurs in the United States. Components can be globally sourced, but build, testing, and quality checks are completed domestically.

Are these exit signs UL 924 listed?

Yes. Models in this category are UL 924 listed and provide a minimum of 90 minutes of emergency illumination for code-compliant egress.

Do they qualify for BAA/BABA/TAA on public projects?

Not automatically. “Assembled in USA” may support certain procurements, but BAA/BABA/TAA compliance depends on the specific program and product documentation. Confirm with the manufacturer’s statements.

What documents should I request for submittals?

Typical documents include a UL 924 listing reference, specification/submittal sheet, certificate of assembly or origin, and any applicable BAA/BABA/TAA letters.

What legend and face options are available?

Most units offer red or green LED legends, field-selectable chevrons, and single- or double-face configurations. Verify local requirements (e.g., letter height in certain jurisdictions).

What battery types are used?

Common chemistries are Ni-Cd or lithium (Li-ion/LiFePO4). Check the spec sheet for runtime, recharge time, and temperature ratings.

Are self-testing models available?

Yes. Many USA-assembled signs include self-diagnostic electronics that automate monthly and annual tests to simplify inspections.

Can these be used in damp, wet, or cold environments?

Choose damp-location models for humidity/condensation. For direct spray or exterior exposure, specify wet-location or cold-weather packages and confirm ambient limits.

What mounting options are typical?

Universal hardware for wall, ceiling, or end-mount is common; many models include a canopy. Always verify included accessories in the submittal.