Wet Location Exit Sign Combos

Wet-location exit sign & emergency light combos combine a sealed LED EXIT legend and adjustable lamps in one weatherproof enclosure (NEMA/IP) so you can mark the door and light the threshold from a single fixture for 90 minutes. Ideal for wash-down rooms, parking decks, and exposed egress points. Explore exit sign & emergency light combos, and for classified areas or heavier construction consider hazardous-location fixtures or die-cast aluminum emergency lights.

EXIT + Lamp Heads Weatherproof Sealed NEMA 4X / IP66 Shared 90-Min Battery Doorway Coverage Self-Testing (select)
Buyers Guide Tips

What to Look for in Wet-Location Exit Sign & Light Combos

  • NEMA/IP + shared battery: One sealed enclosure (e.g., NEMA 4X/IP66) powers the EXIT legend and lamp heads for 90 minutes; check load tables and recharge time for the combined draw in cold/wet conditions.
  • Doorway photometrics: Mount above the door, set sealed chevrons, and aim heads to wash the landing and first run; confirm end-of-discharge illumination at installed height meets code in rain/spray environments.
  • Hardware & upkeep: UV-stable cabinet, stainless fasteners, liquid-tight hub; place indicator/test for floor-level visibility and consider self-testing to streamline hose-down-area inspections.

A wet-location exit sign & light combo mounts above the door to both mark the exit and wash the landing from a single, sealed enclosure. Set the chevrons, aim the heads to cover the first corridor segment, and confirm your shared-battery load keeps both functions on for the full 90 minutes.

Use liquid-tight conduit connections, stainless hardware, and UV-stable cabinets for wash-down bays, parking decks, and exposed egress points. Position the status LED and push-to-test for floor-level visibility; self-testing simplifies monthly and annual checks when units sit in hose-down or wind-driven rain zones.

Wet Location Exit Signs with Lights Combo Collection
Trust & Policies

Filters

6 Products

Wet-Location Exit Sign & Light Combos - Specs & Features

  • Sealed 2-in-1 chassis: One NEMA 4X/IP66 enclosure integrates LED EXIT legend and dual adjustable heads; gasketed joints, sealed pivots, and liquid-tight conduit entry withstand wash-down and rain.
  • Shared battery (90 minutes): Single pack powers the legend and both heads for the full duration; confirm load tables and recharge time for cold/wet environments and door-height installs.
  • Doorway photometrics: Mount above the door, set sealed chevrons, and aim heads to wash the landing/first corridor segment; verify end-of-discharge illumination at installed height meets code targets.
  • Materials & service: UV-stable cabinet, stainless fasteners, corrosion-resistant lens; floor-visible indicator and push-to-test with optional self-testing to streamline hose-down inspections.

FAQs About Wet-Location Exit Sign & Light Combos

When should I use a combo outdoors instead of separate units?

Choose a combo above exterior doors or tight egress points to mark the exit and light the landing from one sealed enclosure—fewer penetrations, simpler wiring, and a single test point.

How does rain/fog affect lamp aiming?

Aim heads to wash the landing and first corridor segment with minimal glare. Verify foot-candles at installed height at the 90-minute mark; adjust for reflective wet surfaces and wind-driven spray.

Will the shared battery still make 90 minutes in cold/wet conditions?

Check the unit’s ambient rating and load tables. Cold temps reduce capacity—choose models rated for your climate and confirm recharge time; some offer self-testing to monitor battery health.

Any wiring tips to maintain the NEMA/IP seal?

Use liquid-tight hubs, drip loops, and stainless hardware. Seat gaskets evenly, avoid upward-facing seams, and re-torque fasteners after service to preserve the enclosure rating.