End Mount Exit Signs – Versatile, Overhead Egress Lighting Solutions

End mount exit signs are designed for ceiling, pendant, or soffit installations where wall mounting isn’t feasible. These fixtures feature side-mounted housings that provide clear visibility across corridors, stairwells, and open spaces. They meet UL 924 and NFPA 101 standards, typically offering a visible legend up to 100 ft away. See all Exit Signs.

UL 924 Compliant LED Edge-Lit / Surface 90-Min Backup End-Mount Ceiling Design 100 ft Viewing
Buyers Guide Tips

What to Look for in End-Mount Exit Signs

  • Compliance & runtime: UL 924 with a minimum 90-minute emergency operation; coordinate specifics with your AHJ under NFPA 101.
  • Legend & visibility: Standard 6 in letters (jurisdictional variants available); viewing distance up to 100 ft; red or green legends as required.
  • Mounting: End-mount canopy/bracket for ceiling, pendant, or soffit; verify J-box pattern and rod/drop length for ceiling height.
  • Faces & orientation: Single- or double-face models; for edge-lit, confirm mirrored/backplate configuration to present both sides when needed.
  • Directional chevrons: Prefer field-selectable arrows to match egress paths and reduce SKU complexity.
  • Power & electronics: Universal 120/277 VAC, solid-state charger, status LED, and test switch for functional checks.
  • Battery: Maintenance-free Ni-Cd or lithium packs sized for 90-minute operation; consider cold-weather heaters for unconditioned spaces.
  • Construction & finish: Clean edge-lit acrylic or durable thermoplastic/metal housings; tamper-resistant hardware in public areas.
  • Environment: Specify damp/wet-location ratings where applicable; use IP/NEMA enclosures and heater kits for cold or wash-down areas.
  • Placement & sightlines: Maintain clear line-of-sight over aisles and doorways; follow height guidance (e.g., mount bottom within ~6′-8″ of egress opening where required).

Ideal for high-ceiling corridors, retail aisles, atriums, and stairway landings, end-mount designs often include dual-voltage support, universal mounting canopies, and low-profile housings. Many models offer field-selectable directional chevrons, edge-lit LED legends, and integrated battery backup for at least 90 minutes.

Best-practice guidance from NFPA 101 recommends mounting the bottom of any exit sign no more than 6′-8″ above the egress opening—end-mount signs satisfy this standard when ceiling mounted above doors or corridors.

What is an end mount exit sign?
It’s an exit sign with a mounting bracket on the narrow end of the housing—ideal for ceiling, pendant, or soffit installations where wall mounting isn't practical and visibility is needed across open spaces.

Looking for other mounting configurations? Explore ceiling-mounted exit signs for overhead installations or wall-mounted exit signs when side visibility and wall placement are preferred.

Filter products

35 Products

End-Mount Exit Signs – Spec Guide

  • Compliance & runtime: UL 924 listed signage with a minimum 90-minute emergency operation; aligns with NFPA 101 egress requirements (verify with your AHJ).
  • Mounting: End-mount canopy/bracket for ceiling, pendant, or soffit installs; confirm junction-box compatibility and drop length for ceiling height.
  • Legend & visibility: Standard 6-in letters (jurisdictional variants available) with viewing distances up to 100 ft; choose red or green legends.
  • Faces & orientation: Single- or double-face models; mirrored/backplate options for edge-lit designs to present the legend on both sides as needed.
  • Directional chevrons: Field-selectable arrows to match the egress path and reduce SKU complexity; maintain consistent sign language across the facility.
  • Power & electronics: Universal 120/277 VAC, solid-state charger, status LED, and test switch for code-required functional checks.
  • Battery: Maintenance-free Ni-Cd or lithium packs sized for 90-minute operation; consider cold-weather heaters for unconditioned spaces.
  • Construction & finish: Clean edge-lit acrylic or durable thermoplastic/metal housings; specify tamper-resistant hardware for public areas.
  • Maintenance & diagnostics: Optional self-testing electronics automate monthly/annual checks; keep test logs per AHJ requirements.

FAQs About End Mount Exit Signs

What is an end mount exit sign?

End mount exit signs have housings designed to install perpendicular to the wall—often from the ceiling or soffit—to provide visibility in corridor centers or high ceilings.

Where are these signs typically used?

They are ideal for long corridors, stair landings, retail aisles, atriums, and other spaces where wall space is limited or sightlines require overhead visibility.

How high should an end mount sign be installed?

NFPA 101 advises that the bottom of the sign should not exceed 6′‑8″ above the top of egress openings—end mount designs help maintain this height when installed overhead.

Do they include emergency backup?

Yes, all models include rechargeable batteries that provide at least 90 minutes of illumination during power failures.

Can they include directional arrows?

Yes, most feature field-selectable directional chevrons to guide occupants along exit routes.

Are there mounting options available?

Yes—end mount exit signs typically come with universal mounting canopies for ceiling, pendant, or soffit installations, accommodating various ceiling types and heights.