Die-Cast Aluminum Exit Signs Red Letter

Die-Cast Aluminum Exit Signs

Rugged and reliable, die-cast aluminum exit signs are built for high-traffic and demanding facilities. These UL 924 listed LED exit signs pair precision-cast housings with long-life battery systems to deliver code-ready egress visibility. Explore all exit signs, or compare wet-location exit signs, self-testing exit signs, and exit sign and emergency light combos.

UL 924 LED Legend 90-Min Backup Tamper-Resistant Wet-Location Options 120/277 VAC
Buyers Guide Tips

What to Look for in Die-Cast Aluminum Exit Signs

  • Housing & durability: Precision die-cast body, gasketed seams, impact-rated lens, and corrosion-resistant hardware.
  • Egress performance: UL 924–verified 90-minute runtime with even, high-contrast legend.
  • Faces & chevrons: Single/double-face and field-selectable chevrons for directional clarity.
  • Mounting & power: Universal wall/ceiling/end mounting and dual 120/277 VAC input.
  • Environment rating: Specify damp/wet-location or enclosure-rated options where exposure demands.
  • Diagnostics: Self-testing availability to automate monthly and annual checks.
What are die-cast aluminum exit signs?
Exit signs built with precision-cast aluminum frames for enhanced strength, longevity, and a clean architectural profile—delivering reliable, code-compliant egress marking in demanding environments.

These fixtures feature vivid red or green LED EXIT legends, field-selectable chevrons, and single- or double-face configurations to match your layout. Universal hardware supports wall, ceiling, or end mounting, while maintenance-free batteries provide at least 90 minutes of emergency illumination for NFPA 101 and OSHA compliance. Many models add self-diagnostic testing to automate inspections.

Die-cast aluminum housings deliver superior impact resistance, heat dissipation, and corrosion protection—ideal for industrial, commercial, and high-traffic areas. For hose-down or exposed installations, choose wet-location rated exit signs. Prefer lighter weight and lower cost? Compare our thermoplastic exit signs.

Filter products

31 Products

Die-Cast Aluminum Exit Signs Spec Guide

Spec Snapshot

  • Compliance: UL 924 listed with a minimum 90-minute runtime; supports NFPA 101 egress requirements. Coordinate final details with your AHJ.
  • Legend & Faces: Uniform LED legend in red/green; field-selectable chevrons; single- or double-face panels. Typical 6" letters rated to long viewing distances—verify per model.
  • Housing & Finish: Rigid die-cast aluminum frame with powder-coat finish, tamper-resistant hardware, and enhanced impact/corrosion resistance for high-traffic areas.
  • Battery Backup: Maintenance-free Ni-Cd or lithium packs providing ≥90 minutes of emergency operation; check recharge time and ambient limits on the cut sheet.
  • Power & Diagnostics: Dual-voltage 120/277 VAC; solid-state charger/automatic transfer, low-voltage disconnect, AC lockout, brownout detection, push-to-test & status LED. Self-testing versions automate monthly/annual checks.
  • Mounting: Universal wall/ceiling/end canopy kits; orient for clear sightlines and chevron visibility along egress routes.
  • Ingress & Environment: Many models offer damp or wet-location listings. For hose-down or exterior exposure, choose wet-location exit signs or NEMA-rated exit signs.
  • Options: Architectural finishes, vandal-resistant faceplates, and accessories to match interior design while maintaining code compliance.

FAQs About Die-Cast Aluminum Exit Signs

Why choose die-cast aluminum over thermoplastic?

Die-cast housings offer superior impact resistance, heat dissipation, and long-term durability—ideal for high-traffic spaces. If weight or cost is your priority, compare thermoplastic exit signs.

Are these fixtures code compliant?

Yes. Die-cast models are UL 924 listed and installed to meet NFPA 101 and OSHA life-safety requirements, including a 90-minute backup duration.

Do they include battery backup?

Most units include sealed internal batteries (Ni-Cd or lithium) providing at least 90 minutes of illumination. See battery backup exit signs for details.

Can these be installed outdoors or in wet areas?

For direct rain or hose-down exposure, choose wet-location exit signs (or NEMA/IP variants). Standard die-cast models are typically indoor or damp-rated—check the listing.

Do die-cast units support self-testing?

Yes. Many models offer self-diagnostic electronics that automate monthly/annual tests. Browse self-testing exit signs.

What mounting options are available?

Universal kits typically support wall, ceiling, or end-mount. Field-selectable chevrons let you set direction on site for flexible layouts.

What legend colors and faces can I choose?

Most die-cast signs offer red or green LED legends and single- or double-face configurations with uniform illumination and high contrast.

Are there vandal-resistant or tamper-resistant options?

Yes. Die-cast frames, hardened lenses, and tamper-resistant hardware are common—ideal for schools, gyms, transit areas, and public facilities.

What if I also need emergency lighting in the same fixture?

Consider exit sign & emergency light combos to reduce fixture count and simplify wiring while staying code-compliant.

How do I verify readability and placement?

Check the model’s viewing distance and character size (e.g., 6" letters) and follow the AHJ’s placement rules to maintain clear sightlines along egress routes.