Wet Location Exit Sign Combos

Wet Location Exit Sign Combos

Wet location exit sign combos combine a waterproof LED EXIT panel with battery-powered emergency lights—ideal for hose-down zones and exposed areas where spray or moisture is unavoidable. For runtime-focused models, see battery-backup exit sign combos; for classified environments, browse Hazardous Location Exit Sign Combos.

UL 924 Listed NEMA 4X / IP66 Rated 90-Min Backup LED Illumination

These weatherproof exit sign combos feature fully gasketed, corrosion-resistant housings built for durability in wet or industrial outdoor settings. All models are UL 924 compliant and meet NFPA 101 standards, delivering at least 90 minutes of emergency egress lighting during a power failure.

Adjustable LED lamp heads flank a sealed LED EXIT legend, forming a rugged, all-in-one fixture. These wet location emergency lights are ideal for food processing plants, car washes, outdoor stair towers, loading docks, and covered walkways.

Features include:

  • NEMA 4X / IP66 housings for water, dust, and impact resistance
  • Field-selectable chevrons for directional egress flexibility
  • Universal mount kits for wall, ceiling, or end installation
  • Self-testing options for automatic monthly and annual diagnostics
💡 What is a Wet Location Exit Sign Combo?
A weatherproof combination fixture that integrates an EXIT sign and emergency lighting in a single sealed unit—built for moisture-rich or outdoor environments.

Common Uses for Outdoor Exit Sign Combos

  • ✔️ Covered exterior walkways and building entrances
  • ✔️ Commercial kitchens and washdown production zones
  • ✔️ Outdoor stairwells, warehouses, and vestibules
  • ✔️ Parking structures, loading bays, and marine enclosures

Wet location exit sign combos are perfect for code-driven installations where separate exit signs and emergency lights are not feasible. These units simplify compliance while ensuring safety and reliability in demanding environments.

Need alternatives? Check out our Damp Location Exit Sign Combos for indoor moisture zones, our Class I Div 2 Exit Sign Combos for hazardous locations, or Die-Cast Aluminum Combos for rugged, architectural installations.

Filter products

10 Products

✅ What to Look for in Wet Location Exit Sign and Light Combos

In wet or wash-down areas, a combo fixture pairs a sealed LED EXIT legend with battery-powered lamp heads to deliver code-ready egress lighting. Explore battery-backup exit sign combos for runtime options, and for hazardous atmospheres see Hazardous Location Exit Sign Combos.

  • UL 924 Certification: Confirms 90-minute emergency illumination and life-safety compliance.
  • Wet-Location Rating: IP66/IP67 or NEMA 4X for rain, hose-downs, and corrosive environments.
  • Gasketed & Sealed Construction: Continuous gaskets, sealed seams, and drain paths protect batteries, charger, and LED heads.
  • Battery Backup: Powers both the EXIT legend and lamp heads for ≥90 minutes; look for push-to-test, status LED, and brownout protection.
  • Photometrics & Coverage: Adjustable heads and sufficient lumens to meet egress foot-candle levels along the path of travel.
  • Power Budget / Remote-Capable: Verify total wattage and remote-head capacity; confirm 120/277 VAC input.
  • Durable Housing Materials: Polycarbonate, fiberglass, or powder-coated aluminum with UV-stable lenses and stainless hardware.
  • Legend & Chevrons: Field-selectable chevrons, single/double-sided options, and red or green letters to match site standards.
  • Mounting & Conduit: Universal surface/ceiling/end mounts with sealed 1/2" NPT hubs or cord grips to prevent intrusion.
  • Self-Testing Diagnostics: Automated monthly/annual tests reduce manual checks and catch failures early; cold-weather heaters where required.

FAQs About Wet Location Exit Sign and Light Combos

What qualifies as a wet location?

A wet location is any area that may be directly exposed to water, rain, spray, or hose-downs. Common examples include outdoor walkways, food processing zones, and open-air loading docks.

Are wet location exit sign combos code compliant?

Yes. All models are UL 924 listed and meet NFPA 101 and OSHA requirements for emergency egress lighting in wet or outdoor environments.

How long do wet location combos operate during power loss?

Built-in battery backup systems provide a minimum of 90 minutes of illumination for both the EXIT sign and integrated emergency light heads.

What materials are used in these weatherproof fixtures?

Most weatherproof exit lights feature housings made from corrosion-resistant polycarbonate, fiberglass, or powder-coated aluminum with sealed, gasketed construction for long-term durability.

Do wet location models offer self-testing?

Yes. Many models include self-testing diagnostics to automate monthly and annual code-required testing, saving time on inspections.

Can these be used in extreme temperatures?

Absolutely. Look for models with wide temperature ratings or optional internal battery heaters—ideal for use in freezers, refrigerated warehouses, or hot climates.