Self-testing exit sign and emergency light combos merge illuminated egress signage with integrated emergency lamp heads in a single, code-compliant unit. A built-in diagnostic controller automates monthly 30-second tests and the annual 90-minute discharge, helping you meet NFPA 101 and OSHA without manual checks. Explore related options: Self-Testing Exit Signs, Self-Testing Emergency Lights, and Remote-Capable Combos.

UL 924 Auto Diagnostic 90-min Backup LED Heads Field Arrows Universal Mount
Buyers Guide Tips

What to Look for in Self-Testing Exit Sign and Emergency Light Combos

  • Compliance & runtime: UL 924 listing with automated monthly 30-second test and annual 90-minute discharge; align with NFPA 101 and your AHJ.
  • Auto-test profile: Verify factory schedule, ability to reschedule window, and manual test initiation without opening the housing.
  • Status indicators: Clear front-panel LED with distinct fault codes (AC, charger, battery, lamp/LED, remote circuit) visible from floor level.
  • Error memory & logs: Retains last test results after power loss; helpful for inspections and maintenance records.
  • Lamp heads & photometrics: Adjustable optics sized to achieve ≈ ≥1 fc average and ≥0.1 fc minimum along egress paths at 90 minutes.
  • Batteries: Maintenance-free Ni-Cd or lithium; confirm recharge time, ambient range, and expected service life; check cold-weather options if needed.
  • Electrical safeguards: Universal 120/277 VAC, brownout protection, low-voltage disconnect, and surge protection for reliability.
  • Remote-head capability: If supported, verify remote output voltage/watts and that diagnostics test remote circuits, not just on-board heads.
  • Mounting & configuration: Universal wall/ceiling/end mounts, single/double-face panels, and field-selectable chevrons for layout flexibility.
  • Damp/wet location: Specify appropriate rating and vandal-resistant housings for exterior or high-traffic areas when required.
  • Serviceability: Accessible test switch, quick-connect battery, and tool-less entry (where available) to speed maintenance and fault clearing.

Under normal power, the unit operates as a standard LED EXIT sign. During an outage, the internal battery powers both the exit legend and the adjustable emergency lamp heads for a minimum of 90 minutes of life-safety illumination. High-efficiency LEDs provide bright output with low energy use and long service life.

The self-diagnostic system continuously monitors AC input, charger status, battery health, and lamp operation. A front-panel LED communicates pass/fail results and fault conditions at a glance—streamlining inspections and reducing maintenance labor.

Most models include universal wall/ceiling/end mounting, field-selectable directional chevrons, and single- or double-face configurations. Options such as wet-location ratings, remote-head compatibility, tamper-resistant metal housings, and cold-weather packages support a wide range of commercial, educational, and institutional applications.

What is a self-testing exit sign combo?
A single egress fixture that integrates an EXIT sign and emergency lights with an onboard controller that runs automatic monthly and annual tests—helping maintain UL 924 and NFPA 101 compliance without manual push-button testing.

Need moisture protection or extended coverage? Pair with wet location exit sign combos or choose damp location exit sign combos for larger areas.

Filter products

18 Products

Self-Testing Exit Sign and Emergency Light Combos – Spec Guide

  • Compliance & tests: UL 924 listing; automated monthly 30-second test and annual 90-minute discharge consistent with NFPA 101 (verify with AHJ).
  • Scheduler & controls: Check factory test schedule, ability to defer/override tests, and manual initiation without opening the housing; confirm lockout during occupied hours if needed.
  • Status & fault codes: Front-panel LED (or display) should indicate AC present, charger, battery, lamp/LED faults, and remote-circuit issues where applicable; visibility from floor level preferred.
  • Error memory & reporting: Retains last test results; provide a quick view of pass/fail history for inspections. Optional dry contacts or network tie-ins are a plus for large sites.
  • Egress photometrics: Adjustable heads sized to achieve ≈ ≥1 fc average and ≥0.1 fc minimum along paths for 90 minutes; confirm spacing tables.
  • Batteries: Maintenance-free Ni-Cd or lithium; verify recharge time, ambient range, and expected service life; cold-weather packages for unconditioned spaces.
  • Electrical & protections: Universal 120/277 VAC, brownout protection, low-voltage disconnect, and surge suppression; confirm remote-head output ratings if supported.
  • Mounting & configuration: Universal wall/ceiling/end mount, single/double-face panels, and field-selectable chevrons to align with site layout.
  • Damp/wet & abuse resistance: Specify appropriate rating and vandal-resistant housings/guards for exterior or high-traffic areas.
  • Serviceability: Accessible test switch, quick-connect battery, and tool-less entry (where available) streamline maintenance and fault clearing.

FAQs About Self-Testing Exit Sign and Light Combos

What is a self-testing combo exit sign?

It’s a 2-in-1 fixture with an LED exit sign and emergency lights that runs automatic monthly and annual diagnostics to help you stay code-compliant.

How does the self-testing system work?

The unit automatically performs a 30-second test every 30 days and a full 90-minute discharge once a year. A status LED indicates pass/fail conditions.

Are manual tests still required?

No push-button tests are required on compliant self-testing models, but a quick visual check of the status indicator is recommended to confirm everything is working.

Do these include battery backup?

Yes. All models include sealed internal batteries to power both the sign and emergency lamps for at least 90 minutes. See our battery backup combos.

Are they UL listed and code compliant?

Absolutely. These fixtures are UL 924 certified and meet NFPA 101 and OSHA requirements for life safety and diagnostics.

Where can I find self-testing models?

View our full collection of self-testing exit sign and light combos for available options and specifications.