Recessed Emergency Lights

Recessed Emergency Lights

Recessed emergency lights provide flush-mounted, architecturally discreet egress illumination. Designed for drop (T-bar) or drywall ceilings, these UL 924–compliant LED fixtures deliver at least 90 minutes of battery backup during power loss—ideal for offices, hotels, lobbies, galleries, and retail spaces. Start at our parent Emergency Lights collection, then explore wet-location emergency lights and battery backup emergency lights for exterior exposure or extended-runtime layouts.

UL 924 Compliant 90-Min Battery Backup LED Illumination Flush Recessed Design Self-Testing (Optional)
Buyers Guide Tips

What to Look for in Recessed Emergency Lights

  • Compliance & runtime: UL 924 listing with a minimum 90-minute operation; align with NFPA 101 and your AHJ.
  • Ceiling type: Confirm T-bar vs drywall kits, plenum suitability, and any fire-rated ceiling requirements or tile replacements.
  • Fixture depth & clearance: Verify plenum depth, joist spacing, and clearances to insulation/MEP to ensure the can and driver fit flush.
  • Aperture & trim: Choose low-glare trims and finishes that match the ceiling; confirm cutout size and flange detail for a clean reveal.
  • Optics & spacing: Aim for corridor/open-area coverage to meet ≈ ≥1 fc average and ≥0.1 fc minimum at 90 minutes; review photometrics for spacing.
  • Aiming & adjustability: Prefer adjustable heads or gimbals to direct light along egress paths and avoid glare on artworks/displays.
  • Power & electronics: Universal 120/277 VAC, solid-state charger/automatic transfer, status indicator, and test switch (visible/remote as required).
  • Battery chemistry: Maintenance-free Ni-Cd or lithium; verify ambient range and recharge time; consider cold-space options if needed.
  • Self-testing: Select diagnostics to automate monthly/annual tests and simplify inspection documentation.
  • Installation method: New-construction bars vs retrofit frames; ensure secure attachment to grid/structure and seismic clips where required.
  • Service access: Provide an accessible panel or below-ceiling access for battery/driver maintenance per code and ceiling constraints.

All models are UL 924 listed and compliant with NFPA 101 life-safety codes. Internal battery systems—typically Ni-Cd or lithium-ion—provide at least 90 minutes of illumination during power outages. Adjustable LED optics offer wide, energy-efficient beam coverage for code-ready egress lighting.

These recessed ceiling emergency lights integrate cleanly into T-bar or gypsum ceilings with new-construction bars or retrofit kits to minimize visual clutter and maintain a low profile. For projects that also require exit signage in one fixture, see our exit sign and emergency light combos.

💡 What is a recessed emergency light? It’s a compact life-safety fixture that installs flush with the ceiling to provide emergency illumination without disrupting your architectural design.

Filter products

6 Products

Recessed Emergency Lights – Spec Guide

  • Compliance & runtime: UL 924 listing; provide a minimum 90-minute operation and align with NFPA 101 (verify with your AHJ).
  • Ceiling type: Specify T-bar grid vs drywall kits; confirm plenum use, tile compatibility, and any fire-rated or smoke-control requirements.
  • Fixture depth & clearances: Verify plenum depth, joist spacing, and setbacks to insulation/MEP to ensure the housing, driver, and battery fit flush without conflicts.
  • Aperture & trim: Choose low-glare trims/finishes; confirm cutout size, flange profile, and ceiling reveal for a clean architectural look.
  • Optics & spacing: Design for corridor/open-area coverage to achieve ≈ ≥1 fc average and ≥0.1 fc minimum along egress paths at 90 minutes; review photometric spacing tables.
  • Aiming & adjustability: Prefer gimbaled or adjustable heads to aim light along the path of egress and mitigate glare on art, glazing, and displays.
  • Power & electronics: Universal 120/277 VAC, solid-state charger/automatic transfer, low-voltage disconnect, status indicator, and accessible test switch (local or remote).
  • Battery chemistry: Maintenance-free Ni-Cd or lithium; verify ambient temperature range, recharge time, and expected service life for maintenance planning.
  • Self-testing diagnostics: Consider automatic monthly/annual test functions with fault indication to simplify inspection recordkeeping.
  • Installation method: New-construction bars vs retrofit frames; confirm secure attachment to grid/structure and include seismic clips where required by local code.
  • Service access: Provide below-ceiling or accessible panel access for battery/driver replacement and testing without damaging finishes.

FAQs About Recessed Emergency Lights

Where are recessed emergency lights typically used?

They’re common in hotels, theaters, offices, galleries, and high-end retail—places that want subtle emergency lighting, clean ceiling lines, and minimal visual clutter.

Are they safe for use in insulated ceilings?

Yes. Choose fixtures with IC-rated housings so they can be in direct contact with insulation while staying safe and code-compliant.

Do recessed emergency lights meet code requirements?

Absolutely. UL 924–listed recessed units provide at least 90 minutes of battery-backed illumination and meet NFPA 101 / OSHA life-safety standards.

Can I retrofit recessed emergency lighting into an existing ceiling?

Yes. Many products are retrofit kits that fit standard ceiling cutouts, so you can upgrade without major demo or rework.

What kind of batteries do these fixtures use?

Most use Ni-Cd, Ni-MH, or lithium packs with automatic charging. Many include self-testing diagnostics to simplify monthly and annual checks.

Are recessed models as bright as surface-mounted emergency lights?

Yes. With high-output LED heads, recessed fixtures can deliver equal or better egress illumination—just with a cleaner, more discreet look.

What is a flush mount emergency light?

It’s a fixture that sits nearly even with the ceiling surface for a low-profile appearance. Recessed emergency lights are a type of flush mount and are ideal where ceiling aesthetics matter.