Recessed Emergency Lights

Recessed emergency lights are ceiling-mounted, flush-mount emergency fixtures that conceal the housing above the ceiling so only a clean trim or door is visible. They still deliver code-required egress illumination for at least 90 minutes during an outage. Every recessed emergency light in this collection is UL 924–listed LED emergency lighting with integral battery backup, giving you commercial-grade protection without exposed “bug-eye” heads.

Use these recessed emergency downlights (sometimes called emergency can lights) in finished corridors, office hallways, lobbies, galleries, stairwells, and other architectural ceilings where you want concealed emergency lighting to disappear into the ceiling plane. See all emergency lights, compare architectural emergency lights, or choose wet-location recessed fixtures for garages, canopies, spray, and wash-down areas.

Need a recessed sign instead of a light? See our recessed exit signs.

Flush Ceiling Trim LED Emergency Lighting Spacing & Photometrics 90-Min Battery Backup Ceiling-Recessed Mount Self-Testing (select)
Buyers Guide Tips

What to Look for in Recessed Emergency Lights

  • Photometrics at height: Select lumen output and optics that achieve required foot-candles on the floor at 90 minutes for your ceiling height and aisle width. Use manufacturer spacing charts for your recessed emergency lighting layout, then aim and lock heads after commissioning.
  • Ceiling & plenum fit: Verify rough-in aperture, can depth, and plenum clearance for T-bar/drop ceilings vs. hard ceilings. Confirm bar hangers, flanges, and any fire-rated or IC-rated requirements before cutting the ceiling.
  • Service access: Make sure batteries and chargers are accessible (from below or above the ceiling) and that the status LED and push-to-test are visible from the floor. Self-testing electronics (select models) reduce lift time for monthly and annual checks.
  • Environment & finish: Match trims to the interior (round/square, matte/metallic) and check ambient temperature range. For spray, garages, and wash-down spaces, use wet-location recessed fixtures; add cold-weather packages where needed to protect 90-minute battery capacity.

Place recessed emergency lights so trims line up with ceiling grids and heads can wash the egress path evenly. Confirm spacing at your mounting height using photometric files and re-check coverage at the 90-minute point. Coordinate cutouts, can depth, and plenum access with ceiling trades so openings stay clean and serviceable.

In galleries, hotels, healthcare corridors, and office lobbies, use asymmetric optics or carefully aimed heads to reduce glare on polished floors and glass. Keep the status LED and push-to-test visible from the floor, and consider self-testing units to minimize lift time for routine inspections.

Recessed Emergency Lights Collection
Trust & Policies

Filters

8 Products

Information Hub: Recessed Emergency Lighting Spacing, Ceilings & Egress Coverage

Diagram showing recessed emergency lights rough-in for drywall, grid or T-bar ceilings, and millwork or wall soffits.
Recessed emergency lights – ceiling and wall rough-in for drywall, grid/T-bar, and millwork/wall conditions.

Spacing & Mounting Height

  • Start with your egress plan: Identify paths (corridors, stairs, lobbies, open areas) and required foot-candles on the floor at 90 minutes per your engineer/AHJ. Recessed emergency lights should be laid out just like general lighting—on a plan, not “eyeballed.”
  • Use manufacturer spacing data: For each fixture family, use spacing charts or point-by-point photometrics at your mounting height to set row spacing and along-the-run spacing. Verify that your grid still meets requirements at the end of the 90-minute battery discharge.
  • High ceilings vs. low ceilings: Taller ceilings push beams wider and dimmer at floor level. For atriums and double-height spaces, move to higher-output LED recessed emergency lights, tighter spacing, or additional heads to keep minimum foot-candles up.
  • Aiming adjustable heads: Cross-aim dual heads to cover the path and keep beams off walls and glass where possible. Lock aim after commissioning so coverage doesn’t drift after ceiling work or cleaning.

Ceiling Types & Rough-In Choices

  • T-bar vs. hard ceilings: T-bar grid ceilings typically use bar hangers and flanges that sit on the tile; gypsum or plaster ceilings rely on framing and drywall flanges. Confirm the rough-in method and flange detail before ceilings are closed.
  • IC, non-IC & fire-rated: In insulated plenums, specify IC-rated recessed emergency lights or maintain the clearance the manufacturer calls out. For fire-rated assemblies, use listed fire-rated housings or approved firestop kits that preserve the rating of the floor–ceiling system.
  • Trim style & finish: Choose round vs. square, door vs. open downlight, and finishes (white, black, metallic) to match the ceiling design. Keep emergency trims aligned with grids, reveals, or decorative cans for a clean, flush ceiling view.
  • Clash check: Reserve plenum space around each housing for service clearance; avoid conflicts with sprinklers, diffusers, ductwork, and cable trays that could block access to the battery compartment later.

Access, Testing & Maintenance

  • Below vs. above-ceiling access: Some ceiling-mounted emergency lights open from the room side (hinged doors, drop-in plates); others are serviced from the plenum. Confirm which type you’re specifying and coordinate access panels if the plenum is not readily reachable.
  • Status indicator visibility: Keep the status LED and push-to-test visible from the floor so inspections don’t require removing tiles or opening access doors. Avoid placing trims where furniture or soffits will block line-of-sight.
  • Self-testing vs. manual: Self-testing electronics (select models) automate monthly function tests and annual 90-minute tests and log faults, reducing lift time. For manual-test projects, ensure there’s a clear path for a ladder or lift under each unit.
  • Battery environment: Match battery chemistry and any cold-weather package to the plenum temperature. Extreme cold or heat can shorten runtime and battery life if the fixture is not rated for those conditions.

Use-Case Scenarios

  • Finished corridors & lobbies: Flush trims with adjustable heads or downlights that blend with architectural cans; use asymmetric optics or shallow aiming to keep glare off glass and polished stone floors.
  • Galleries, offices & high-end interiors: Square or slot-style trims that align with lighting patterns; match finish to nearby luminaires so emergency fixtures visually disappear in normal operation for retail, hospitality, and workplace projects.
  • Garages, canopies & wet areas: Choose wet-location recessed or semi-recessed units with vandal-resistant doors and, if needed, cold-weather options to preserve 90-minute capacity in exposed or unconditioned spaces.
  • Retrofits: Semi-recessed units or models that fit standard cutouts simplify upgrades from surface “bug-eye” heads to cleaner, ceiling-integrated emergency lighting.

Code tip: Always confirm required light levels, mounting heights, and testing intervals with your local AHJ. Use manufacturer cut sheets and photometric summaries in your submittal package so the recessed emergency lighting layout and ceiling details are clearly documented.

Recessed Emergency Light Decision Framework (Checklist)

  1. Map the egress paths. Mark corridors, stairs, lobbies, and large open areas on your life-safety plan and note ceiling heights in each zone.
  2. Identify ceiling & environment. For each area, confirm T-bar vs. hard ceiling, presence of insulation, fire-rating, and whether the space is dry, damp, or wet.
  3. Select fixture families. Choose LED recessed emergency lights with the right ratings (IC/non-IC, damp/wet, cold-weather), housing style, and trim aesthetics for each ceiling type.
  4. Lay out spacing & aiming. Use manufacturer photometrics to set fixture spacing at your mounting height; plan head aiming to wash the path, then lock adjustments after the system is commissioned.
  5. Plan access & testing. Decide on self-testing vs. manual testing, confirm where batteries and controls are accessed, and ensure the status LED and test switch are visible and reachable from the floor.
  6. Document for submittal. Include fixture schedules, cut sheets, spacing layouts, and any fire-rated/IC notes in your submittal package so the recessed emergency layout is clear to the AHJ and ceiling trades.

FAQs About Recessed Emergency Lights

Do recessed emergency lights work in IC or fire-rated ceilings?

Yes—choose the correct housing. IC-rated recessed emergency lights are designed for contact with insulation; non-IC housings require clearance. For fire-rated assemblies, specify listed fire-rated housings or approved firestop kits per the ceiling’s rating and local code.

How do I confirm 90-minute egress levels with recessed downlights?

Use the manufacturer’s photometric files/spacing charts for your mounting height and aisle width, aim heads (or select beam spreads), and field-verify with a light meter at the 90-minute mark—not just at initial output. This confirms your battery backup recessed lighting still meets required foot-candle levels at the end of discharge.

Where is the battery and how is service performed in a recessed install?

Batteries/chargers or emergency drivers are typically in the recessed housing or a nearby ceiling plenum box. Ensure below-ceiling or above-ceiling access per the submittal, and keep the status LED/push-to-test visible from floor level to speed inspections on ceiling-mounted emergency lights.

Any tips to reduce glare on polished floors or glass walls?

Select asymmetric optics or aim heads at a shallow angle to “wash” the floor. Avoid pointing directly at reflective surfaces and lock adjustments after commissioning to keep the beam where it belongs and maintain low-glare egress lighting.

Where are recessed emergency lights typically used?

Recessed emergency lights are ideal for commercial interiors where you want discreet, concealed life-safety lighting—office corridors, hospitals, schools, hotels, restaurants, retail stores, galleries, and other spaces with finished ceilings that benefit from a flush, architectural emergency light instead of a surface “bug-eye” fixture.