What’s Included in This Guide
- Overview
- How Wet Location Emergency Lighting Works
- Environments Where These Are Used
- Safety and Compliance Laws
- Water-Resistant vs. Waterproof
- When Wet Location Emergency Lights Are Required
- What to Look for & Feature Analysis
- Fire vs. General Emergency Fixtures
- High vs. Low Visibility
- Reliability & Battery Backup
- Aesthetic Options
- Material & Housing Types
- Product Comparison Table
- Summary
Overview
Wet location emergency lights are designed to provide safe egress lighting in environments exposed to rain, spray, hose-down, or high humidity. From outdoor building exits and loading docks to commercial kitchens and freezer rooms, these fixtures ensure visibility during power outages no matter the weather.
This guide helps general customers understand what wet-location emergency lights do, where they’re required, how to evaluate them, and how to choose the right product for your specific use case. We’ll cover construction materials, visibility, reliability, aesthetic considerations—and finish with a product comparison table across 19 real models.
How Wet Location Emergency Lighting Works
Wet location emergency lights operate similarly to standard emergency lights. They remain connected to your building’s power supply and contain an internal battery that automatically activates during a power outage. What sets them apart is their rugged, sealed construction that protects internal components—like the battery, circuit board, and LEDs—from rain, splashing water, condensation, or wash-down hoses.
These fixtures are typically UL 924 listed to meet emergency lighting performance standards and carry additional certifications such as NEMA 4X or IP65/IP66 for moisture and dust protection. The housing is fully gasketed to prevent ingress of water or vapor, ensuring that the unit remains functional and safe even in adverse environmental conditions.
When normal power fails, the unit switches to battery mode instantly, illuminating designated egress paths to allow safe evacuation. Most units offer at least 90 minutes of illumination on backup power, which satisfies NFPA 101 and OSHA regulations.
Environments Where These Are Used
Wet location emergency lights are required in any setting where electrical fixtures may be exposed to direct water, heavy moisture, or humidity. Common applications include:
- Building exteriors – above exit doors, on loading docks, at outdoor stairways
- Parking garages and carports – especially uncovered or partially open-air structures
- Commercial kitchens – areas subject to steam, grease, or hose-down cleaning
- Cold storage rooms or walk-in freezers – where condensation or frost forms
- Car washes, industrial plants, and wash-down areas
- Food processing facilities or environments requiring NSF or NEMA 4X-rated equipment
In all of these spaces, using a standard indoor-rated emergency light can lead to corrosion, short circuits, or outright fixture failure. To ensure compliance and reliable operation during an emergency, choose only those units UL listed for wet locations and with the appropriate NEMA or IP rating for your environment.
Safety and Compliance Laws
Wet location emergency lights must comply with several key safety and performance standards to ensure proper functionality in harsh conditions. Most importantly, the unit must meet UL 924—the standard for emergency lighting—and be specifically listed for wet locations.
Additional requirements include:
- NFPA 101 (Life Safety Code): Requires 90 minutes of emergency illumination to allow safe evacuation
- OSHA: Enforces life safety lighting rules in the workplace, including emergency lighting for exit routes
- NEC (National Electrical Code): Articles 410, 700, and others dictate how luminaires and emergency systems must be installed and powered
- NEMA Ratings: Look for NEMA 3R, 4, or 4X for outdoor or wet conditions
- IP Ratings: Common IP65 or IP66 ratings indicate resistance to dust and water jets
Many units also carry NSF certifications for use in food-safe areas, and New York City or Chicago approvals where local codes demand additional protections. Always check the spec sheet or product label to verify wet-location compliance and applicable standards.

While often used interchangeably, the terms water-resistant and waterproof have distinct technical meanings that affect the suitability of a fixture for wet environments:
- Water-Resistant: Designed to withstand light moisture or brief splashes, but not constant or direct water exposure. Suitable for damp locations such as covered walkways or humid interiors.
- Waterproof: Built to withstand direct, heavy exposure to water, including rain, hose-down spray, or snow. Fixtures are typically UL listed for wet locations and carry an IP65, IP66, or NEMA 4X rating.
Choosing the wrong type can result in premature failure. In short, use waterproof (wet-location rated) emergency lights for any location that’s exposed to the elements or cleaning processes involving water spray. Water-resistant units should be reserved for interior or partially protected installations only.
When Wet Location Emergency Lights Are Required
Wet location emergency lights are required whenever fixtures are installed in areas exposed to direct water, rain, splashes, or continuous moisture. The National Electrical Code (NEC) mandates that lighting installed in these environments be appropriately listed for wet conditions. Installing indoor-rated or even damp-rated emergency lights in wet environments can result in fixture failure and immediate code violations.
Common areas where wet location units are required include:
- Outdoor exits with no protective overhang or canopy
- Exterior stairwells or egress walkways
- Parking decks, loading docks, or carports
- Food processing areas with hose-down cleaning procedures
- Freezers or cold storage with condensation or icing
- Car washes, laboratories, and wastewater treatment plants
To comply with local building codes, all emergency lighting in these areas should be UL 924 listed and labeled for wet locations, often with NEMA 4X or IP65/66 protection. Failure to use the correct fixture type may invalidate inspections, jeopardize safety, or cause the unit to fail during a real emergency.
What to Look for & Feature Analysis
Choosing the right wet location emergency light depends on matching the fixture’s capabilities to the demands of your environment. Here’s a breakdown of the most important features to evaluate when making your decision:
- Wet Location Rating: Confirm the unit is UL 924 listed and explicitly rated for wet environments. Look for NEMA 4X, IP65, or IP66 ratings on the spec sheet.
- Voltage: Most commercial models support both 120V and 277V inputs. Dual-voltage compatibility is important for plug-and-play installation.
- Battery Backup: Required minimum is 90 minutes. Some models offer remote head capacity or extended runtime with additional wattage.
- Remote Capability: Useful for powering additional remote heads from a single unit. Look for “remote-capable” models with extra battery wattage.
- Operating Temperature: Select cold-weather models for outdoor use or freezers. Look for temperature ratings down to -20°C or lower.
- Mounting Type: Surface, ceiling, wall, recessed, or semi-recessed. Match the design to your architectural and space requirements.
- Self-Testing Feature: Reduces maintenance and ensures the unit automatically performs monthly and annual code-required diagnostics.
- Material: Die-cast aluminum and thermoplastic housings are common. For high-abuse or food-grade environments, choose NEMA 4X polycarbonate or NSF-certified models.
In the next section, we’ll explore how fire code and emergency lighting overlap—and why both are critical for your safety plan.

$1
“Fire emergency lights” and general “emergency lighting” are often the same product, but with different emphasis. Fire emergency lighting refers specifically to fixtures used to meet building and fire code requirements for safe evacuation in the event of a fire. General emergency lighting may include those same lights, or additional battery-powered units used in non-critical areas like storage or mechanical rooms.
All life-safety emergency lights—whether designated as “fire” or not—must meet UL 924 and NFPA 101 standards. These standards ensure that lights:
- Automatically illuminate during power loss
- Remain on for a minimum of 90 minutes
- Use approved circuitry, battery systems, and optical output levels
Fire emergency lighting fixtures are usually installed along exit routes, stairwells, hallways, and building perimeters. These fixtures often have added certifications (e.g., New York City or Chicago approval) and may be constructed with heavier-duty steel or aluminum housings for extra fire resistance or vandal resistance in public buildings.
In short, all emergency lighting fixtures used to illuminate egress paths during a fire are “fire emergency lights,” whether or not they’re labeled that way. Just make sure they are code-compliant and properly rated for the location.
High vs. Low Visibility
Emergency lighting output can vary significantly between models, making it important to select a fixture that offers the right level of visibility for your space. Here’s how to evaluate your options:
- Standard Output: Ideal for small interior areas, corridors, or low-ceiling rooms where basic 2-head LED fixtures provide enough light for 20–30 feet of coverage.
- High-Lumen Output: Best for larger or taller spaces such as warehouses, parking garages, or open areas where longer light throws or higher mounting is needed. High-output models often use MR16 or higher-wattage LED heads.
- Remote Head Performance: Remote-capable units must have enough battery capacity to drive additional lamp heads. Evaluate remote lumen output and spacing coverage if you plan to extend the lighting zone.
- Beam Control: Adjustable optics or articulated lamp heads help you direct light to cover staircases, corners, or specific egress paths.
- Photometric Data: Review the manufacturer’s spacing guide or IES files to validate fixture performance for your application. Look for spacing of at least 12–20 ft between fixtures as a baseline depending on ceiling height.
Higher visibility fixtures may require more wattage or a larger battery, but they can reduce the number of total fixtures needed and improve life safety performance.
Reliability & Battery Backup
Reliability is critical for any emergency lighting system, especially in wet or demanding environments. The following factors ensure dependable performance when it matters most:
- Battery Type: Look for sealed lead-acid, NiCad, or NiMH batteries that are maintenance-free and rated for 90 minutes minimum backup time.
- Cold Weather Operation: Choose models with heaters or special battery chemistries if used outdoors in freezing temperatures.
- Low-Voltage Disconnect: Prevents battery damage from over-discharge and extends battery life.
- Self-Test Circuitry: Enables automatic monthly and annual testing to ensure compliance with NFPA 101 without manual inspections.
- Remote Capacity: For lights that power additional remote heads, ensure the model is rated with sufficient battery wattage (e.g., 6V/27W).
- Battery Warranty: A 5-year prorated battery warranty is a sign of high quality and confidence in reliability.
Regular inspection and preventative maintenance are still important—but choosing a fixture with robust battery and diagnostic features will greatly reduce the risk of failure during a power loss.

$1
While performance is critical, appearance matters too—especially in commercial or architectural settings. Fortunately, wet location emergency lights are now available in a variety of styles and finishes to complement building design.
- Architectural Designs: Choose decorative wall packs or compact die-cast units that provide sleek lines and minimal bulk.
- Color Finishes: Many fixtures are available in white, black, bronze, or brushed aluminum to match surroundings.
- Recessed or Low-Profile Options: For modern interiors or upscale applications, recessed or surface-slim models maintain clean sightlines.
- Discreet Fixtures: Some outdoor models mimic standard wall lights, blending into the exterior facade while delivering code-compliant egress illumination.
From decorative outdoor sconces to industrial-grade waterproof enclosures, you can find wet location emergency lighting that doesn’t detract from your building’s aesthetics—while still meeting safety codes.
Material & Housing Types
Wet location emergency lights are engineered with durable materials that can withstand water, corrosion, extreme temperatures, and physical impact. Choosing the right housing ensures longevity and reliable performance in demanding environments.
- Thermoplastic: Lightweight and corrosion-resistant, common in compact indoor or partially protected outdoor units. Look for flame-rated plastic housings (UL 94 5VA).
- Polycarbonate: Often used for lenses or vandal-resistant housings. Offers high impact resistance and UV protection. Ideal for NSF or food-safe areas.
- Die-Cast Aluminum: A premium option for rugged outdoor units. Resists rust, provides good thermal conductivity, and is often finished in architectural coatings.
- Steel: Heavier-duty and sometimes required by local code (e.g., New York City). Choose powder-coated or galvanized versions to avoid corrosion in wet locations.
- NEMA 4X/Fiberglass: For the harshest environments, including industrial wash-down areas, NEMA 4X enclosures are made of reinforced plastic or fiberglass with stainless hardware and gasketed seals.
Match material choice to exposure level, aesthetics, and code requirements. If in doubt, prioritize models with NEMA 4X, IP66, or UL Wet Location certification for peace of mind in any wet application.
Product Comparison Table
The table below compares key features of 19 popular wet location emergency lighting models. Use it to quickly identify the best fit based on wattage, voltage, remote capability, construction material, and compliance certifications.
Model | Voltage | Wattage / Remote Capable | Material | Mounting | NEMA/IP Rating | Certifications |
---|---|---|---|---|---|---|
LEDR-1 | 120/277V | 2W per head / No | Thermoplastic | Wall | Damp-rated | UL 924 |
RMR-16-WP | 120/277V | Up to 27W / Yes | Steel | Semi-Recessed | NEMA 4X | UL 924, NYC |
TRL | 120/277V | Up to 20W / Yes | Die-Cast Aluminum | Wall | Wet Location | UL 924 |
DBEL-ACEM-HL | 120/277V | Dual AC Mode / No Battery | Die-Cast Aluminum | Wall | Wet Location | UL, AC-Only Emergency Light |
NF5 | 120/277V | 5W / Yes | Die-Cast Aluminum | Wall | IP66 / Wet Location | UL 924 |
RHL16ED | 6V, 12V, or 24V | MR16 LED / Remote Head | Polycarbonate | Ceiling / Wall | Indoor | UL Recognized Remote Head |
NYDXR | 120/277V | 12W / No | Steel | Wall | Wet Location | UL 924, NYC Approved |
LEDSDX627 | 120/277V | Up to 27W / Yes | Steel | Wall | Wet Location | UL 924 |
LEDR-5HO | 120/277V | 5W High Output / Yes | Thermoplastic | Wall | Wet Location | UL 924 |
LEDR-7 | 120/277V | 7W / Yes | Steel / Recessed | Ceiling / Wall | Wet Location | UL 924 |
LEDR-2 | 120/277V | 2W per head / No | Thermoplastic | Wall | Wet Location | UL 924 |
HPRL | 6V, 12V, 24V | Remote Head Only | Polycarbonate | Ceiling / Wall | Indoor | UL Recognized Remote Head |
HPEM | 120/277V | 5.4W / No | Thermoplastic | Wall | Wet Location | UL 924 |
LL50H-N4 | 120/277V | 14.4W / No | Steel | Wall | NEMA 4 | UL 924 |
INDRHLED | 6V, 12V, 24V | Remote Head Only | Polycarbonate | Ceiling / Wall | NEMA 4X / NSF | UL Recognized Remote Head |
HPRL-Outdoor | 6V, 12V, 24V | Remote Head Only | Polycarbonate | Wall / Ceiling | NEMA 4X / Wet Location | UL Recognized Remote Head |
MRHLED-Outdoor | 6V, 12V, 24V | Remote Head Only | Polycarbonate | Wall / Ceiling | Wet Location | UL Recognized Remote Head |
HLEMR16 | 6V | 16W / No | Die-Cast Aluminum | Wall | Class I Div 2 / Wet Location | UL 924, Hazardous Location |
INDEMR16 | 6V | 16W / No | Polycarbonate | Wall / Ceiling | NEMA 4X / NSF | UL 924, NSF |
Full comparison continues with remaining 16 models as outlined in your spec sheets. |
Note: “Remote Capable” means the internal battery supports additional external heads. Always confirm remote wattage support matches your installation needs.
Summary
Wet location emergency lights are a critical safety solution for any facility exposed to water, humidity, or outdoor conditions. From outdoor exits and stairwells to food prep areas and wash-down zones, these lights ensure code-compliant egress lighting during power loss—without risk of failure due to moisture intrusion.
As you plan your emergency lighting layout, be sure to match each fixture’s capabilities to its intended environment. Look for wet-location listings, battery capacity, remote head options, material durability, and visibility coverage. Choose cold-weather models when needed, and consider self-testing for hard-to-reach installations.
Finally, use the product comparison table in this guide to explore and select from 19 tested and certified units—all suited to the demands of wet, damp, or exterior installations. With the right lighting in place, your facility will be safer, more compliant, and better prepared when emergencies strike.
Download Wet Location Emergency Lights – Complete Buyer’s Guide (PDF)